10
5. POWERPACK OPERATION
5.7 Decrease Button (-)
A single press of this button decreases chlorine production by approximately 5%. To turn OFF
chlorine production it is necessary to press the button several times to make sure all chlorine
indicator LEDs are off.
5.8 Increase Button (+)
A single press of this button increases chlorine production by 5%. When all ten lights are ON the
chlorine production is 100%.
5.9 LED Indicator Chart
A Swing tag is attached to the power pack cell cable for quick reference. There are two LEDs on the
front of the power pack that indicate various states, conditions, and faults. These are as follows:
“+/-“ LED is SOLID GREEN: Chlorinator Cell is outputting in the Forward Direction.
“+/-“ LED is BLINKING GREEN: Chlorinator Cell is outputting in the Reverse Direction.
! WARNING LED is SOLID GREEN: No faults detected, and everything should be functioning
normally.
! WARNING LED is SOLID ORANGE: LOW SALT – have your pool water tested by your local
pool shop; check for calcium build-up on the Cell, insufficient water flow over the Cell, Cell
plates are worn meaning the Cell is reaching the end of its life, check Power Pack Cell Cable
Plug connection to the cell.
! WARNING LED is BLINKING ORANGE: HIGH SALT – have your pool water tested by your
local pool shop; high salt causes excessive heat and wastes electricity. You can save on
power by keeping your salt within range. Turn output down by 10% per 500ppm that the water
is over salted or drain pool water and add fresh water. NOTE: Either of these two actions will
save electricity that would cost more than the cost of the water.
! WARNING LED is SOLID RED: INTERNAL TEMPERATURE TRIP – check that your salt level is not
too high. The fault will reset once the transformer cools down.
! WARNING LED is BLINKING RED: WATER FLOW FAULT – check for air cavities in the cell
chamber causing the gas sensor on the cell cap to not be in the water, raise the speed of the
pump or check that pump is working, remove any air locks, check valves and skimmer/pump
baskets, check flow switch (if applicable). It may take a few minutes for this indicator to reset.
At any stage that the Water Flow LED is ON pressing either the INCREASE or DECREASE buttons
will try to start up the unit again.