5. POWERPACK OPERATION
5.10 Chlor Boost
The XR Series Salt and Mineral Chlorinator can be set to Chlor Boost(Chlorine Boost) for 24
hours by default and automatically sets the chlorine output to 100% during that time. To enter
chlor boost hold the “+” and “-“ buttons in simultaneously for approximately 3-5 seconds.
After releasing the buttons, the LED’s 2 and 4 will flash on for 5 seconds to indicate the unit
has entered “Chlor Boost”. It you wish to change the “Chlor Boost” time setting you can do so
by pressing the “+” or “-“ buttons this will cause the unit to cycle through settings.
Pressing “+” will have the effect of increasing the hours from 24 up to 28, 32, 36 and back to 4,
8, 12, 16, 20, 24 hours respectively. Pressing “-“ will have the effect of decreasing the hours
from 24 to 20, 16, 12, 8, 4 and then back up to 36, 32, 28 and 24 hours respectively.
LED’s 1 through to 10 will turn on for 5 seconds and then off for 1 second to indicate that
“Chlor Boost” has been activated.
To turn off “Chlor Boost” at any time before its running time, press and hold the “+” and “-
buttons together for 3-5 seconds. The unit will indicate that it is deactivating “Chlor Boost” by
causing the “flow fault” LED (LED 12) to flash three times and then the unit will revert to its
normal function with LED indicating regular output.
5.11 Start Up Procedure
Plug the Power Pack 3 pin plug into a suitable weatherproof RCD protected 10amp outlet
and then plug the pump into the socket at the base of the XR Chlorinator.
Ensure the Cell is connected and make sure the Cell Cable is inserted fully into the
connections on the Cell Cap.
Turn the 10-amp wall outlet supply switch to “ON”.
Ensure the Cell Switch is turned ON and the timer is in ON mode.
The pump should start up and prime.
LED’s 1,2 and/or 3 will light up for 0.5 seconds.
The last saved output set point is displayed on the ten output LED’s.
The Indicator LED should be SOLID GREEN.
Either the “Forward” or “Reverse” LED status will be displayed on the “+/-” LED.
Ensure that once you have performed the initial start-up you reset the timer to “AUTO”
mode.
Run the chlorinator for 6-10 hours per day in the summer and 3-6 hours per day in the winter.
5.12 Temporary Change of Polarity
Start with the unit “ON” and identify if it is operating in the “Forward” or “Reverse” direction.
Turn the unit OFF at the Cell Switch.
Wait 3-5 seconds and then turn the Cell Switch ON.
The polarity should change and the direction LED “+/-” should display the opposite direction.
Is this does not work then perform the OFF WAIT 3 SEC ON process again.
The unit will stay in this direction for 2 minutes and then revert to the original direction.
The polarity will change every 7 hours in normal operation (factory set). This polarity change
can be permanently set to between 4 and 10 hours if required. Only lower this time if the Cell
is not cleaning (mainly due to very high calcium levels).