5. POWERPACK OPERATION
5.1 Timer “MANUAL” Button –
9
n/a in “NO TIMER” Models
This button on the timer moves a black line on the Timer LCD face to the following modes:
• AUTO – the unit is in AUTO mode and the Timer controls the operating hours. See Section 6 for
Timer Setting.
• ON – the unit is ON, and both the pump AC Socket and Cell (providing Cell Switch in ON) will be
powered up.
• OFF – the unit is OFF, and both the pump AC Socket and Cell will be OFF.
5.2 Cell Switch
This switch position determines whether the cell is turned ON or OFF when power is supplied to it
from the timer.
• O – pressing the switch in at the “O” position turns the Cell OFF in all models. For units with a
Timer the pump is controlled by the Timer not the Cell Switch.
• I – pressing the switch in at the “I” position turns the Cell ON in all models. The backlight on the
Cell Switch will light up. For units with a Timer This will only work if the Timer is turned ON.
• Changing Direction – while the unit is running you can change direction by turning OFF the cell
switch, wait 3 seconds then turn it ON again. The direction should change. If it does not, then
repeat this again and it should change direction. Please note, “+/-” LED is ON: cell is in Forward
direction and “+/-” LED is blinking: cell is in Reverse direction.
5.3 Circuit Breaker
The Circuit Breaker only operates the Cell circuit and not the pump circuit. A circuit breaker is an
automatically operated electrical switch designed to protect an electrical circuit from damage
caused by overcurrent, overload, or short circuit. It can be reset by pressing the button in after it
has tripped. It may be damaged if you supply excessively high levels of salt through the cell.
5.4 AC Socket (Pump Outlet) – N/A in “NO TIMER” Models
The AC Socket allows the pump to be electrically operated and controlled by the Power Pack.
WARNING: If you fail to control the pump this way you must install a flow switch mechanism to control
the electrical supply to the Power Pack, to prevent gas build-up if the pump stops or a valve is closed.
5.5 Cell Lead
The proprietary Cell Lead comes complete with moulded gold plated/brass connectors and is
connected to the cell via a watertight plug top.
5.6 Output LEDs
There are ten green chlorine production indicating LED’s. Each indicator corresponds to 10% of
chlorine Production. Each solid LED represents 10% and a blinking LED represents 5%. If you require
55% setting you will have LED 1-5 (i.e., 10% to 50%) is solid ON and LED 6 (60%) will blink.