5. POWERPACK OPERATION
5.13 Modifying the Polarity Change
12
Times
IMPORTANT: The platinum coating on the cell plates may not last as long with quicker change
over times as a percentage of wear on the coating is related to the number of polarity
changes.
To Permanently set the polarity change frequency, follow the directions below:
Start with the unit “OFF”.
Press and hold the “DECREASE” button.
Turn the unit “ON”.
Release the button and the selected reversing time will display. The default will be set to 7
hours, and LED 7 will display. If LED 4 displays, this indicates that the reversing time is 4
hours and this can be increased by increments of 1 hour which will correspond with the
number of LED’s displayed. If LED 1, 2 and 3 display this means the reversing period is 10
hours.
To change the reversing hours, press the “DECREASE” or “INCREASE” button to switch from
one reversing hour to another.
Once you have selected the reversing time you require, turn the unit “OFF”. The new
setting will apply next time you turn the unit ON”.