10 6028021 Rev. 1
NSTALLATION
I
B
D
C
A
GA0005.ill
SHORT ARM
(45 degree position only)
C
Open
D
Close
RC1550.ill
C
D
RC1549.ill
C
A
B
D
IMPORTANT: Make sure hydraulic system
is purged of air before checking attachment
functions outlined below (see Step 9).
With no load, cycle all functions several
times.
Check functions for operation in accor-
dance with ITA (ISO) standards.
Clamp and rotate a maximum load, check
for smoothness and normal rotation.
Check for leaks at fittings, revolving
connection and cylinder rod ends.
AUXILIARY VALVE FUNCTIONS
ROTATE
(Driver's view)
A
Counterclockwise (CCW)
B
Clockwise (CW)
Hoist Down
Tilt Forward
Hoist Up
Tilt Back
WARNING: Make sure all
personnel are clear of the
clamp during testing.
10
SWING
(Bilge handling shown)
A
(Push button) Extend
B
(Push button) Retract
RC0963.ill
LONG ARM
(vertical & horizontal
positions only)
C
Release
D
Clamp
A
B
Cycle attachment functions
NOTE: Extension or retraction of swing
cylinder swings attachment up or down,
left or right, depending on which orienta-
tion clamp arms are rotated to.