EasyManua.ls Logo

Case IH Axial-Flow 5088 - Safety Systems: Neutral Start, Presence, and Backup Alarm Elaboration

Case IH Axial-Flow 5088
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 - SAFETY/DECALS
22
NEUTRAL START SYSTEM
Make sure the Neutral Start System is operating
properly by doing the following:
1. With the propulsion handle in a position other
than Neutral, the engine should not start.
2. If engine does start, Neutral Start System needs
adjustment. See your dealer.
OPERATOR’S PRESENCE SYSTEM
Make sure the Operator’s Presence System is
operating properly by doing the following:
1. With the Combine running, place the Park Brake
On and the transmission in Neutral.
2. With everyone clear of the machine engage
separator and feeder switches.
3. After separator and feeder are running, stand up
out of the seat. In approximately 7 seconds the
feeder should shut OFF. If not, Operator
Presence System needs repair, see your dealer.
BACKUP ALARM
The machine is equipped with a backup alarm. When
the machine is moving in reverse, the alarm will
sound.
RH07G084