SECTION 2 - CONTROLS, INSTRUMENTS AND OPERATION
2ï110
Flywheel Knotter
This alarm message appears in case the flywheel
shearbolt or the knotter drive PTO shearbolt fails and
the pick up speed sensor is not functioning. In this
case it is no longer possible to make the distinction
between a flywheel shearbolt failure or a knotter
shearbolt failure.
Press the escape key to stop the audible alarm.
The message remains on the screen until after
replacement of the shearbolt and the machine is
restarted and running above (>600 rpm).
Refer to Section 4-36
234
Knotter trip system defect
Continuous tripping of the knotter puts knots on the
bill hook which do not get wiped off correctly and
component damage may result.
This alarm message will appear when the knotters
are tripped 2 times or more shortly after each other
within 5 stuffer cycles (no or almost no feeding in
between the knotter cycles).
Press the escape key to stop the audible alarm. 235
Stop the baler (PTO OFF and flywheel brake ON)
Investigate and correct the problem.
The message will disappear automatically.