SECTION 21 - TRANSMISSION 105
2.3
1. Drain plug
2. Oil level plug
F27717
2
1
LUBRICATION
Oil capacity................................................ 14 litres
Suggested oil .......... Axcela Trans XHD MAT3525
Daily
Check oil level daily with engine running at idle (600
rpm) and oil at 82 - 93 °C.
Maintain oil level at full mark.
Normal drain period
Normal drain period and oil filter change are for av-
erage environment and duty cycle condition.
Severe or sustained high operating temperature or
very dusty atmospheric conditions will cause accel-
erated deterioration and contamination.
For extreme conditions judgement must be used to
determine the required change intervals.
Z Every 1000 hours change oil filter.
Z Every 1000 hours drain and refill system as fol-
lows: drain with oil at 65 - 93°C.
- Drain transmission.
- Oil filter, remove and discard, install new filter.
- Refill transmission (14 litres).
- Run engine at idle (600 rpm) to prime converter
and lines.
- When oil temperature is at 82 - 93 °C adjust oil level
to full mark.
NOTE: it is recommended that oil filter be changed
after 100 hours of operation on new, rebuilt or re-
paired unit.