CONTROLLER
3 - 16
CX EXCAVATORS
CURRENT CONDITION CHK2
Continued
TRANSISTOR OUTPUT (0=OFF, 1=ON)
Battery Relay – Should be a 1 here anytime the key switch is turned on.
Can not observe off signal.
Cushion Valve (off/on) – While the engine is running push the cushion
switch. A 1 should appear in the cushion valve field. When the cushion
switch is pressed again the 1 should be changed to a 0.
Swing shut off – With the key switch on push the swing lock switch the
swing shut off field should change to a 1. When the swing lock is pushed
again the field should change to a 0.
TR2 0 0 0 0
Battery Relay
Cushion Valve (off/on)
Swing Shut Off
Not Used