HYDRAULIC,PNEUMATIC,ELECTRICAL,ELECTRONICSYSTEMS-PRIMARYHYDRAULICPOWERSYSTEM
Controlvalve-GeneralspecicationMechanicalHandControl
Loadervalveonallmodels
SR130,SR150,SR175,SV185,SR200
MainReliefSetting:3000psi(+145/-0)at23USgpm
(A1)3263psi(+145/-73)
(B2)3336psi(+145/-73)
CircuitReliefSetting:
(A2)3481psi(+145/-73)
LoaderSpool:28lb
LoaderSpoolDetentPosition:65lbIN;58lbOUT
BucketSpool:29lb
MaximumSpoolForcewithBlocked
PortsatFullFlow:
Minimumreserveforceonallspoolstobegreaterthan5lb
OperatingVoltage=14V
MaximumPower=22W
ElectricalRequirements:
Polarity=Power:Pin1orA,Ground:Pin2orB
Workportlockoutsolenoid:DeutscheDTseries
EHAuxiliaryPRV:DeutscheDTseries.
ElectricalConnectorTypes:
Spoolpositionsensor:DeutscheDTseries
OperatingT emperatureRange:-30-107°C(-22-225°F)
(P)SupplyInlet
(T)TankReturn
(A1)LiftCylinderBaseEnd
(B1)LiftCylinderRodEnd
(A2)TiltCylinderRodEnd
(B2)TiltCylinderBaseEnd
(A3)AuxiliaryMaleCoupler
(B3)AuxiliaryFemaleCoupler
(PLV)WorkportLockoutPilotSupply
(PLV)(Drain)WorkportLockoutTankReturn
(P2)HighFlowInlet
(V)EHPRVSupply
PortIdenticationChart:
(L)EHPRVTankReturn
8442386625/07/2011
A.10.A/18