7. TESTING: MODULE QW-3403
7-1. MEASURING CURRENT CONSUMPTION
�) Apply a voltage of 3.0 V.
2) Perform AC.
3) Wait two seconds.
4) Measure the current consumption.
The current consumption should be 2.21 μA or less.
7-2. CHECKING THE MODEL
CHECKING THE LCD SEGMENTS
Timekeeping mode
ACCURACY CHECKING
MODEL CHECKING
++
Except for
Except
for
Any Button
Except for
All litLight alternates
Except
for
TIME ZONE CHECKING
Note:
The watch returns to the Timekeeping mode when it is left untouched for 1 to 2 hours after the last
button operation. (Auto Return)
The watch returns to the Timekeeping mode when the alarm goes off.
The Auto Light function is disabled when the watch enters the test mode.
7-3. ACCURACY CHECKING
�) While in the Timekeeping mode, hold down
A
and press
D
and
C
at the
same time.
2) Then all the segments are displayed and the LCD drive signals are changed
to the test signals so that you can check the accuracy with a quartz timer.
Measure the accuracy value in the following conditions.
SENSOR GATE TIME
LCD 2 seconds
3) Exit the Accuracy Checking mode.
Press
D
to go to Model checking mode.
Press any button except for
D
to return to the Timekeeping mode.