– 35 –
IT-G500
Manual Test
DC power supply unit
DC ammeter
Turn the right lock switch for the battery pack cover to the “LOCK” position.
Diode
(IF=3.0 A Max.)
DC voltmeter
Y
Low Voltage Detection
No. Operation Test Details
1
Select [6].Low Voltage Detection. (MENU-5)
Adjust the DC power supply output to 3.3 V and
press the “ENT” key.
IT-G500 automatically turns OFF.
2
Adjust the DC power supply output to 3.7 V and
turn ON IT-G500.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.
Y
Current - W-LAN
No. Operation Test Details
1
Select [3].Current - W-LAN. (MENU-5) Check that the current value is within 350 to
450 mA.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.