– 36 –
IT-G500
Automatic Test
Y
Current - Run mode
No. Operation Test Details
1
Select [1].Current - Run mode. (MENU-5) Automatically judges if the current value is
within 400 to 500 mA.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.
Y
Current - Sleep mode
No. Operation Test Details
1
Select [2].Current - Sleep mode. (MENU-5) Automatically judges if the current value is
within 100 to 200 mA.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.
Y
Current - 2D Scanner
No. Operation Test Details
1
Select [5].Current - 2D Scanner. (MENU-5) Automatically judges if the current value is
within 600 to 750 mA.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.
Y
Current - Laser / 2D Scanner
No. Operation Test Details
1
Laser model
Select [4].Current - Run mode. (MENU-5)
2D Scanner model
Select [5].Current - Run mode. (MENU-5)
Automatically judges if the current value is
within 350 to 450 mA.
If OK:
The screen returns to the menu screen.
If any problem:
An error indication is displayed.
Press the “ENT” key to return to the menu
screen.