— 13 —
4-3. Current consumption
1. General
When consumption of a battery is early, check.
2. Conditions
Set QV-2900UX to “PLAY” mode.
3. Preparation
(1) Voltage regulator.
(2) Ammeter.
4. Adjustment procedure
(1) Current consumption (DC in = 6.0 ± 0.1 [V])
Make sure that current consumption is less than 500 mA in PLAY mode.
Make sure that current consumption is less than 650 mA in REC mode.
(Flash charge current is not included)
(2) Lower the voltage from 6 V as shown below then make sure the battery warning indicator changes.
DC in = 4.80 ± 0.05 [V] (one indicator is off )
DC in = 4.50 ± 0.05 [V] (two indicators are off)
DC in = 4.15 ± 0.05 [V] (All the indicators are off)