EasyManuals Logo

Casio PCR-T520 Service Manual

Casio PCR-T520
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
– 33 –
SE-S400/SE-S800/PCR-T500/PCR-T520/SE-C450
SE-S3000/SE-S900/PCR-T2300/PCR-T2400/SE-C3500
[12] Time & Date Setting/Time & Date Display
[Function]
Allows you to check or change the time (hour, minutes, seconds) and date (year, month, day) that
are currently set.
[12-1] Time & Date Setting
[Operation]
<Time setting>
Command : h
h m m s s
0
0
7
0
k
hh Hour mm Minutes ss Seconds
The new settings are printed out when the it is complete.
<Date setting>
Command : y
y m m d d
0
1
7
0
k
yy Year mm Month dd Day
The new settings are printed out when the it is complete.
[12-2] Time & Date Display
Command :
7
0
or
1
7
0
k
To end the display, press the
C
key.
[Display of the Result]
YY/MM/DD HH:MM SS
[13] Drawer Open Test
[Function]
Tests whether drawers operate correctly. The drawer sensor checks every two seconds while
the drawer open test is performed in nite times. Only when the drawer is closed, the drawer is
reopened.
[Operation]
Command : n
0
9
1
k
n: Number of times to run
0 Once (Can be omitted)
1 ~ 9 In nite loop (To forcibly terminate the test, press the
C
key.)
[Display of the Result]
DRW OK
[Printout of the Result]
DRW 91
DRW OK
END 91

Other manuals for Casio PCR-T520