37
9-6. Operation of each test
[ 1 ] Batch test 1
[Function]
RAM test, test print, time setting, buzzer test and drawer open test are performed continuously.
[Operation]
Refer to the page for the details of the following tests.
Operation : 2 SUBTOTAL
The following tests are performed automatically.
(1) RAM test : WRITE/READ all block test
(2) Test print
(3) Times setting : Set the following data.
Arranged data : 2002 December 31, 23:5930
(4) Buzzer : Ring the one shot buzzer.
No print or display in this test
(5) Drawer open : Opens only drawer 1.
(6) Receipt issuance
BATC H 2
RAM WR OK
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
DATE 01/12/31
TIME 23:59-30
DRW 1 OK
END 2
Print Test
[Print]
*When normally printed
BATC H 3
DISP OK
DISP 7SEG OK
BACK LIGHT OK
END 3
[Print]
*When normally printed
[ 2 ] Batch test 2
[Function]
Display test and backlight test are performed continuously.
[Operation]
Refer to the page for the details of the following tests.
Operation : 3 SUBTOTAL
The following tests are performed automatically.
(1) Display test : All LCD dots and 7 segments (LCD/Reared Disp)are displayed, and all LEDs of the
tact switch are lit.
Press any key to go on to the next test. (Same in the backlight test also)
(2) 7 segments display test : 7 segments (LCD, Reared Disp) are displayed.
(3) Backlight test
Perform the backlight test.
The backlight changes to the next color when any key is pressed.
Refer to the Backlight test for details.
(4) Receipt issuance