Regulation of burners
Regulation of the “MINIMUM” position on the burners.
To regulate the minimum position on the burners, follow the procedure below:
1. Turn on the burner and turn the knob to its MINIMUM position (small
ame).
2. Remove the knob from the tap set for standard pressure. The knob is
found on the bar of the tap itself.
3. Place the tap bar on the work top, use a small screwdriver that ts the
(gold) screws located at the lower part of the tap and turn the xing
screw to the right or left until the ame of the burner is regulated in the
most suitable manner to MINIMUM.
4. Make sure that the ame does not go out when changing the position
quickly from MAXIMUM to MINIMUM position.
Caution
The regulation described can only be carried out with
burners that use methane gas and city gas (where
available), whereas the screw must be fully tightened
in a clockwise direction on burners using liquid gas.