Set the Unit’s IP address and the reply address. To enable the settings that were changed, cycle the power supply.
* If the IP address changes, do not forget to change the send destination of commands.
Setting Up the Network (Only Initially and When Settings Are Changed)
2
IP Address
Subnet Mask
Default Gateway
Reception Port Setting
Reply IP Address
Reply Port Setting
192.168.3.2
255.255.255.0
192.168.3.1
4561
192.168.3.10
4562
@00E01192.168.003.00230CRLF
@00E02255.255.255.00035CRLF
@00E03192.168.003.00131CRLF
@00E040456149CRLF
@00E05192.168.003.01033CRLF
@00E06045624CCRLF
@00OEFCRLF
1
Setting the Manual/External Mode Selector to External
Set the Manual/External Mode Selector to EXT to set External Mode. The value set with external control is displayed on the digital window.
* Although it is possible to set the external control setting even the manual/external mode selector is set to manual mode, the setting will not be activated until the
manual/external mode selector is set to external mode.
Setting the Light Intensity
Specify the channel and set the light intensity.
3
@02OF1CRLF
@02N0151CRLF
@02F07584CRLF
Resetting the Light Intensity and Lighting Mode
@00OEFCRLF
@00N014FCRLF
@00RF2CRLF
Checking the Unit Status
@00O004FCRLF
@00N0351CRLF
@00CE3CRLF
Setting the Lighting Mode
4
@01OF0CRLF
@01N0352CRLF
@01S0458CRLF
To Set ON/OFF Signal in ON/OFF Mode
5
@FFO1BCRLF
@FFN027CCRLF
@FFL048CRLF
To Check the Setting Status
@00MEDCRLF
@00N0250CRLF@00OF075.S04.L060CRLF
Setting Procedures
8
Control with External Signals (Continued)
*9) Default setting for trigger logic switch is HIGH =‘1(ON)’ and LOW =‘0(OFF)’.
*10) There is no received data when timeout error occurs.
*11) Received command for setting status check (F999.S99.L9) F999=Light intensity setting (F000 to F255), S99=Lighting mode setting (S00 to S10), L9=ON/OFF setting (L0: Not lit / L1: Lit)
@ 0 1 F 1 2 5
*8) Checksum
*7) ON/OFF setting from Ethernet communications without regards to trigger logic switch, turned OFF at ‘0’ and ON at ‘1’. ON/OFF setting will not be held after turning the power off.
When operating Ethernet communications and trigger signal input at same time in ON/OFF mode.
When Trigger logic switch is at HIGH: if ether controls setting to OFF setting, Light unit will be turned OFF
When Trigger logic switch is at LOW: if ether controls setting to ON setting, Light unit will be turned ON
Initialize the Network Setting
If the IP address setting and others is incorrect, you will not be able to connect to the Control Unit. You will also not be able to reset the IP address
and others. If that occurs, use a pointed object to press the external control reset switch on the front panel to reset all settings to their default values.
To enable the reset settings, cycle the power supply
* The lowest byte (two characters) of 17F
is taken, so the checksum is 7F.
Example: Setting the Light Intensity of Channel 2 to 125
Byte 2Byte 1 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
40 hex 30 hex 31 hex 46 hex 31 hex 32 hex 35 hex
Header Sent commandChannel
17F hex
Total
ASCII (hexadecimal)
Character
The codes of the ASCII characters from the header to the
send command are added, the lowest byte is converted to
hexadecimal, and two characters are sent.
To restore the external control setting to default value, send the following command.
All Channel Initialization
(when there is a command error)
Send the following command to check the Unit status.
Checking the Unit status
(normal)
(when there is a set value out of range error)
Setting example
Setting the L3 light
intensity to 75
Send data
Receive data when OK
Receive data when NG
Setting example Send data
Receive data when OK
Receive data when NG
Setting example Send data
Receive data when OK
Receive data when NG
Setting example Send data Receive data when OK
Receive data when NG
Setting Send data
Receive data when OK
Receive data when NG
Setting Send data
Receive data when OK
Receive data when NG
(when there is a command error)
Specify the channel and set the lighting mode.
Setting the L2 lighting mode
to 200 µs in Strobe Mode
(when there is a set value out of range error)
Specify the channel and set ON/OFF signal.
(When there is checksum error)
(When there is checksum error)
When checking the setting status, send the following command after specify the channel.
Set items , , and when using Continuous Mode.
1 2
3
Set items , , , and when using ON/OFF Mode.
5
1 2 3
Set items , , , and when using Strobe Mode.
1 3 42
Item Setting example Send data Receive data when OK Receive data when NG
@00N014FCRLF
(when there is a command error)
@00N0351CRLF
(when there is a set value
out of range error)
(If Intensity=75, Strobe mode=200μs, Light unit=OFF)
Make sure that the main power source is turned ON.
To turn all light units OFF
To check the setting
status of L1.