EasyManua.ls Logo

CDN ProAccurate Q2-450X - User Manual

CDN ProAccurate Q2-450X
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Perfect For
• Thincutsofmeat,shorpoultry
Easy To Use
• 6secondresponse
• Data-hold
• Bigdigit
• Temperatureguideonsheath
Features
• NSF
®
Certied
• 1.5mmthintip
• 2.75"/7.0cmstem
• Waterproof
• Shatterproof
• Food-safeABSplasticwithBioCote
®
• Stainlesssteelstem
• Fieldcalibration
• On/offbutton
• Auto-offafter10minutes
• Sheathcanbeusedashandleextension
• 2-waymounting:pocketclip/rope
• Battery&instructionsincluded
Note:Removestickerfromdisplaybeforeuse.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthatappears
onthedisplayisshowninBOLD CAPS.
Battery Installation
Thebatteryisinstalled.ReplacebatterywhenLCD
becomesdim.
1.Removebatterycoveronthebackwithacoin.
2.InstalloneLR44batterywithpositive(+)sideup.
3.Replacethebatterycover.
Operating Instructions
A. Temperature Measurement
1.PresstheON/OFFbuttontoturn
theQ2-450Xon.
2.Afteruse,presstheON/OFFbuttontoturn
theQ2-450Xoffandconservebatterylife.
TheQ2-450Xautomaticallyturnsoffafter
10minutesofinactivity.
B. Temperature Scale
Pressthe°F/°Cbuttontoselecttemperature
readinginFahrenheitorCelsius.
C. Data-Hold
BeforewithdrawingtheQ2-450Xfromthefood,
presstheHOLDbutton.Thiswill“hold”the
readinguntilpressedagain.HOLDappearsinthe
upperrightcornerofthedisplay.
D. Max Mode
MaxModeisalwaysworkingbehindthescenes,
continuallystoringthehighesttemperature.
1.PresstheMAXbuttontodisplaythehighest
temperature.MAXappearsonthedisplay.
2.Thedisplayautomaticallyreturnstothe
temperaturemodeafterafewseconds.
3.PresstheMAXbuttonfor3secondsormoreto
clearthestoredMAXvalue.
Model: Q2-450X
ProAccurate
®
Pocket Thermometer
-40 to +450°F/-40 to +230°C
Question and Answer IconNeed help?

Do you have a question about the CDN ProAccurate Q2-450X and is the answer not in the manual?

Summary

Battery Installation

Install LR44 Battery

Install one LR44 battery with the positive (+) side facing up.

Replace Battery Cover

Replace the battery cover after installing the battery.

Operating Instructions

Temperature Measurement

Press ON/OFF to turn on and off. Auto-off activates after 10 minutes of inactivity.

Temperature Scale Selection

Press the °F/°C button to select Fahrenheit or Celsius temperature readings.

Data-Hold Function

Press HOLD before withdrawing to freeze the reading; 'HOLD' will appear on the display.

Max Mode Operation

Press MAX to display the highest temperature recorded. Returns to normal mode automatically.

Self-Calibration Procedure

Prepare Calibration Mixture

Place the stem into a mixture of 3 parts ice and 1 part water.

Initiate Calibration

Press the CAL button for 2 seconds. The display will be blank for 2 seconds.

Verify Calibration Result

Release CAL button; 32.0°F/0°C should appear to confirm calibration.

CDN ProAccurate Q2-450X Specifications

General IconGeneral
TypeDigital Thermometer
Accuracy±1% of reading or ±1°C (±2°F), whichever is greater
MaterialStainless Steel
DisplayLCD
Auto-offYes
Range-40 to 450°F / -40 to 232°C
Resolution0.1°F
Battery1.5V Button Battery
Measurement Range-40 to 450°F / -40 to 232°C
Response Time6 seconds

Related product manuals