Model: TCTW572
WATERPROOF
FOLDING THERMOCOUPLE THERMOMETER
-58 to +572°F/-50 to +300°C
FOR THIN CUTS OF MEAT AND
GENERAL PURPOSE COOKING
NSF
®
Certied
4-way rotating display
2-3 second response
1.5 mm thin tip
4.33"/11.0 cm probe
Waterproof (IPX7: protected from water up to
3 feet/1 meter for 30 minutes)
Extra big digit
Backlit display
Field calibration
Automatic on/off
Food-safe ABS plastic with BioCote®
304 stainless steel probe
Temperature guide on thermometer
Mounting: loop
Two AAA 1.5V IEC LR03 alkaline batteries (included)
Note: Remove label from display before initial use.
Clean the thermometer probe before each use.
Simply ip down the rapid response thermocouple
probe and insert it into food as thin as 1/8-inch.
Note: In the following instructions, names of the control
buttons are shown in CAPS. Function information that
appears on the display is shown in BOLD CAPS.
BATTERY INSTALLATION
Replace battery when LCD becomes dim.
The display ashes fast when the batteries need
to be replaced.
1. Power off the unit before installing the batteries.
A malfunction may occur if the power is on
when the battery is installed. If a malfunction
occurs, press the RESET button in the battery
compartment or restart the device.
2. Using a small Phillips screwdriver, remove the
screws on the back by turning them counter
clockwise.
Note: Be careful to use a properly-sized screwdriver as a
screwdriver too large will strip the screwtops.
3. Remove the cover completely.
4. Install two 1.5V AAA batteries observing polarity
shown in compartment.
5. Replace the battery cover.
Important: THE WATER RESISTANT FEATURE REQUIRES
MAINTAINING THE RUBBER GASKET EVENLY WITHIN THE
GROOVE.
6. Fasten the screws on the back by turning them
clockwise, being careful not to over-turn.
OPERATING INSTRUCTIONS
A. On/Off
1. Flip down the probe to turn the thermometer on.
2. The TCTW572 will automatically turn off after
10 minutes of inactivity.
3. Flip the probe back into the case to turn the
thermometer off and conserve battery life.
CAUTION: Probe may be HOT after use. Always wear a heat
resistant glove to touch the stainless steel probe during or
just after cooking. Do not touch with bare hands.
B. Temperature Scale
To select temperature reading in Fahrenheit or
Celsius:
1. Using a small Phillips screwdriver, remove the
screws on the back by turning them counter
clockwise.
Note: Be careful to use a properly-sized screwdriver as a
screwdriver too large will strip the screwtops.
2. Remove the cover completely.
PO Box 10947 Portland, OR 97296-0947 Tel 800 338-5594 Fax 800 879-2364 Web CDNkitchen.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CDN TCTW572 and is the answer not in the manual?

CDN TCTW572 Specifications

General IconGeneral
BrandCDN
ModelTCTW572
CategoryThermometer
LanguageEnglish

Related product manuals