Fabricant de Contrôle d’Accès depuis 1985
Manufacturing Access Control since 1985
The installer’s choice
Receiver type: Supereheterodyne.
Demodulation: AM/ASK.
Operating frequency: 433.92 Mhz.
Sensitivity (for good signal): -115 dBm.
Input load: 50 Ohm.
Power supply: 12 o 24 V ac/dc.
Current consumption (@12Vdc) from 25 mA to 90 mA (max)
N° of relays: 2 (1 NO and 1 NO / NC).
Max power on relay output: 24VA max 48Vdc .
Memory capacity: 100 transmitters
Security protocol Keeloq® Hopping code
N° of code combinations 2exp64
Operating temperature: from -20 to + 70 °C.
Dimensions (Fig. 2): 105 x 45 x 28 mm.
Weight: 65 gr.
Relay operating mode Pulse, step, timed
Delay from 1 sec. to 24h:59 min.
This Erone receiver SEL2641R433-XPL (Fig. 1) employs rolling-code technology - a
special algorithm keeps the transmitter(s) and receiver synchronised and secure. This
receiver has 2 relay outputs, each having dry contacts.
Programming of transmitters can be carried out either directly on the reciever using the
2 push buttons, or remotely using the buttons of the transmitter.
General parameters of the receiver (relay time etc) can only be done using the 2 push
buttons of the receiver.
All programming steps are displayed on the backlit LCD display.
The internal data can be saved/restored to/from an external memory module.
The receiver location is very important for the best operation of the
system. Place the receiver away from interference sources such as
magnetic elds or radio emissions. The installation and the positioning
of the antenna is also important. Before nalising location or installing
the antenna, it’s advisable to make some tests on site.
The distance between 2 receivers must be at least 1.5 metres.
Hereby, CDVI Wireless Spa, declares that the radio equipment type
SEL2641R433-XPL is in compliance with directive 2014/53/EU. The
full text of the EU declaration of conformity is available at the following
internet address: www.erone.com.
2 RELAY RECEIVER SEL2641R433-XPL
2
Technical Specications
3
Wiring
4
Compatible transmitters
5
Warnings
S2TR2641E1, E2, E4, E2M
SETR2641AM1, AM2
S5TR2641E2, E4
S3TR2641T1, T2, T4
S7TR2641E4
SETR2641-TM
I/O Connections
Terminal Description Terminal Description
1 0V 6 Relay 2-C
2 12 Vac/dc 7 Relay 2-NO
3 24 Vac/dc 8 Relay 2-NC
4 Relay 1-C 9 Antenna GND
5 Relay 1-NO 10 Antenna
(*) NOTE: The tuned antenna, SEA433, is recommended to optimise the
performance.
95
105
45
28
www.erone.com - www.cdvigroup.com
Fig.1
Fig.2
Fig.3
1
Introduction
F1001000078
www.erone.com - www.cdvigroup.com
EN