Fabricant de Contrôle d’Accès depuis 1985
Manufacturing Access Control since 1985
The installer’s choice
Receiver type: Supereheterodyne.
Demodulation: AM/ASK.
Operating frequency: 433.92 Mhz.
Sensitivity (for good signal): -115 dBm.
Input load: 50 Ohm.
Power supply: 12 o 24 V ac/dc.
Current consumption (@12Vdc) from 25 mA to 90 mA (max)
N° of relays: 2 (1 NO and 1 NO / NC).
Max power on relay output: 24VA max 48Vdc .
Memory capacity: 100 transmitters
Security protocol Keeloq® Hopping code
N° of code combinations 2exp64
Operating temperature: from -20 to + 70 °C.
Dimensions (Fig. 2): 105 x 45 x 28 mm.
Weight: 65 gr.
Relay operating mode Pulse, step, timed
Delay from 1 sec. to 24h:59 min.
This Erone receiver SEL2641R433-XPL (Fig. 1) employs rolling-code technology - a
special algorithm keeps the transmitter(s) and receiver synchronised and secure. This
receiver has 2 relay outputs, each having dry contacts.
Programming of transmitters can be carried out either directly on the reciever using the
2 push buttons, or remotely using the buttons of the transmitter.
General parameters of the receiver (relay time etc) can only be done using the 2 push
buttons of the receiver.
All programming steps are displayed on the backlit LCD display.
The internal data can be saved/restored to/from an external memory module.
The receiver location is very important for the best operation of the
system. Place the receiver away from interference sources such as
magnetic elds or radio emissions. The installation and the positioning
of the antenna is also important. Before nalising location or installing
the antenna, it’s advisable to make some tests on site.
The distance between 2 receivers must be at least 1.5 metres.
Hereby, CDVI Wireless Spa, declares that the radio equipment type
SEL2641R433-XPL is in compliance with directive 2014/53/EU. The
full text of the EU declaration of conformity is available at the following
internet address: www.erone.com.
2 RELAY RECEIVER SEL2641R433-XPL
2
Technical Specications
3
Wiring
4
Compatible transmitters
5
Warnings
S2TR2641E1, E2, E4, E2M
SETR2641AM1, AM2
S5TR2641E2, E4
S3TR2641T1, T2, T4
S7TR2641E4
SETR2641-TM
I/O Connections
Terminal Description Terminal Description
1 0V 6 Relay 2-C
2 12 Vac/dc 7 Relay 2-NO
3 24 Vac/dc 8 Relay 2-NC
4 Relay 1-C 9 Antenna GND
5 Relay 1-NO 10 Antenna
(*) NOTE: The tuned antenna, SEA433, is recommended to optimise the
performance.
95
105
45
28
www.erone.com - www.cdvigroup.com
Fig.1
Fig.2
Fig.3
1
Introduction
F1001000078
www.erone.com - www.cdvigroup.com
EN

Other manuals for CDVI SEL2641R433-XPL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CDVI SEL2641R433-XPL and is the answer not in the manual?

CDVI SEL2641R433-XPL Specifications

General IconGeneral
BrandCDVI
ModelSEL2641R433-XPL
CategoryReceiver
LanguageEnglish