4.4 ELECTRICAL CONNECTION
4.4.1 Safety rules
Beforeperforminganyoperation,readandapplythefollowing:
▪ Make sure that the main electric cabinet to which the machine is connected is connected to the earth circuit
and is adequately protected as required by the regulations in force in the country where the machine is in-
stalled.The socket to which the machine is connected must have a slow acting safety switch calibrated to 4 A
(230V) or 8A (115V).
▪ Check that the mains voltage and frequency correspond to the values indicated on the machine identification
plate.
▪ The socket to which the machine is connected must be dimensioned to support the power absorbed up to a
maxi mum of 1.1 kW.
4.4.2 Connection
The machine is supplied with a single-phase cable to which a plug conform to the regulations must be connected.
If an extension needs to be used, bear in mind that the wire cross-section may not be less than 2.5 mm
2
. Make
sure that the extension is arranged so that it does not constitute a risk or obstruction.
WARNING
!
IT IS
CEI EN 50110-1 (NFPA.
4.5 PNEUMATIC CONNECTION
If the machine is equipped with a pneumatic locking/release spindle and/or zero weight lift, it needs to be fed
with compressed air at 7-10 bar. The compressed air coupling is positioned on the rear of the machine. The com-
pressed air must be clean and dry. The pipes and pipe fittings must be properly connected by appropriately trained
personnel. The warranty does not cover damage caused by the absence of an adequate air filtration system.