Input Impedance: 10MΩ
Max. Input Voltage: 1000V DC or 750V rms AC
- By µA, mA or A range:
Frequency response: 0 ~ 40kHz
Input current range: ≥1/4 of the rms AC for the range
(higher input voltage at higher frequency)
- Max. input current:
mA jack
(
µA ranges
)
: 4mA,
mA jack
(
mA ranges
)
: 400mA,
10A jack: 10A
- Overload protection:
µA
、
mA ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting).
NOTE:
The range by DUTY of the Hz range is larger than that of the
voltage range or current range.
3.2.9 Relative Humidity
(
on RH and humidity display
)
Range Resolution Accuracy
20 - 95%
0.1 dB ± 3.5%dB at 94dB, 1kHz sine
wave
- Typical instrument frequency range: 100 ~ 8000Hz