TRMS Clamp Meter
3
3-5 Alternating Current ( )
Range Resolution Accuracy Overload Protection
600A 0.1A
1.9%±5dgts(50~60Hz)
2.5%±5dgts(45~500Hz)
1000Arms
1000A 1A
3-6 Alternating Current (Peak Model)
Range Resolution Accuracy
Overload Protection
1000A 1 A
±2.9% ± 5dgts
1000Arms
3-7 Resistance ()
Range Resolution Accuracy Overload Protection
600 0.1
±1% ± 2dgts
600Vrms
6K 0.001K
60K 0.01K
600K 0.1K
3-8 Continuity
Range Resolution Accuracy Overload Protection
600 0.1
±1% ± 2dgts
600Vrms
Ohm function Buzzer<100
3-9 Capacitance Measurement ( )
Range Resolution Accuracy Overload Protection
6 μF 0.001 μF
±3% ± 10dgts
600Vrms
60 μF 0.01 μF
600 μF 0.1 μF
Note: minimum CAP measurement range > 0.01 μF
3-10 Frequency (Hz) & Duty Cycle (%)
Frequency(Hz) (Autorange)
Function Range Resolution Accuracy Sensitivity
Overload
Protection
Current
Frequency
600Hz 0.1Hz
±0.2% ±2dgts
(30~6KHz)
3Arms 1000Arms
6KHz 0.001KHz
Voltage
Frequency
600Hz 0.1 Hz
±0.2% ±2dgts
(10~60KHz)
5Vrms 600Vrms
6KHz 0.001KHz
60KHz 0.01KHz
Input impedance: 700 k
Duty Cycle (%)(Voltage)
Range Resolution Accuracy Sensitivity
Overload Protection
1~99%(1-500Hz)
0.1%
±0.5%
duty
5Vpp
600Vrms
2~98%(500~1KHz)