page 11
Features
and
functions
5.1.3. Automatic closing (Autoclose Mode)
The D5-Evo and the D10-D10 Turbo sliding gate operators have the
facility to automatically close the gate after it has opened. When
enabling this feature, the time that the gate stays open is by default
fifteen seconds (this time is adjustable*).
As described in the previous section Autoclose is selectable with
Standard and Reversing Modes (page 9) and by default the function is
off. However, Autoclose is automatically enabled in Condominium Mode.
We highly recommended that a safety beam is installed
across the gate entrance and connected to the Closing Safety
Beam input on the D5-Evo, the D10 and the D10 Turbo.
if you enable Autoclose Mode, in order to prevent the gate
from closing on people, pets or vehicles
* It is possible to adjust the delay before the gate closes in one second
increments from zero seconds to four minutes. The default time is five seconds.
5.1.3.1. Autoclose Override
Automatic closing can be
overridden in Standard and
Reversing Modes by pressing
and holding the button of the
remote control or intercom gate
release for no less than three
seconds. The gate response will
be to start opening and then to
stop as soon as the Autoclose
Override feature is activated.
On releasing the button, the
gate will continue opening until
fully open
Your gate will stay open until
you use the remote control or
intercom gate release to close
the gate. The D5-Evo, the D10
and the D10 Turbo will then
revert to normal Autoclose
operation
The Autoclose
function cannot be
overridden in
Condominium
Mode
It is possible to adjust
the override time or
FIGURE 12
Press and hold remote
control pushbutton;
gate will start to open
Gate stops to indicate
that Autoclose Override
has been engaged
Release pushbutton;
gate will continue to open
fully and stay open
the override time or hold down the button in order to
override Aautoclose in one second increments from one to
ten seconds. The default time is three seconds