Comprehensive list of safety precautions for operating the amplifier, covering water, heat, ventilation, and power.
Alerts users to dangerous voltage, electric shock risks, polarized plug issues, and the need for qualified service.
Describes the Bridge/Stereo/Parallel switch, 5-way binding posts, and Speakon connectors for speaker output.
Explains that protection features like speaker relay circuitry are active on power-up and when issues occur.
Describes initial power-up, thermal, short circuit, DC voltage, subsonic frequency, and current limiting protection.
Illustrates the mode select switch for setting Stereo, Parallel, or Bridged Mono operation.
Lists rated output power for CV-900, CV-1800, CV-2800 in Stereo and Bridged Mono modes across various impedances.
Details Signal to Noise Ratio, Distortion, Input Sensitivity, Voltage Gain, Output Circuitry, and Damping Factor.
Covers cooling method, input/output connectors, protection types, power requirements, dimensions, and net weight.
Presents a summary of technical specifications including rated output power, performance metrics, and physical details.
| Signal to Noise Ratio | >100dB (A weighted) |
|---|---|
| Input Sensitivity | 0.775V |
| Input Impedance | 20kΩ Balanced, 10kΩ Unbalanced |
| Dimensions | 3.5" x 19" x 15.2" (88 x 482 x 386mm) |
| Weight | 26.5 lbs (12 kg) |
| Frequency Response | 20Hz - 20kHz |
| THD | <0.1% |
| Connectors | XLR |
| Total Harmonic Distortion | <0.1% |