CESSNA
AIRCRAFT
COMPANY
MODEL
336
SERVICE
MANUAL
NOTE:
There
are
certain
general
precautions
and
rules
concerning
the
fuel
system,
which
should
be
observed
when
performing
the
operations
and
procedures
in
this
section.
These
are
as
follows:
WARNING:
REMOVE
ALL
IGNITION
SOURCES
FROM
THE
AIRPLANE
AND
VAPOR
HAZARD AREA.
SOME
TYPICAL
EXAMPLES
OF
IGNITION
SOURCES
ARE
STATIC
ELECTRICITY,
ELECTRICAL
POWERED
EQUIPMENT
(TOOLS
OR
ELECTRONIC TEST
EQUIPMENT
-
BOTH
INSTALLED
ON
THE
AIRPLANE
AND
GROUND
SUPPORT
EQUIPMENT),
SMOKING
AND
SPARKS
FROM
METAL
TOOLS.
WARNING:
OBSERVE
ALL
STANDARD
FUEL SYSTEM
FIRE
AND
SAFETY
PRACTICES.
a.
During
all
fueling,
defueling,
tank purging,
and
tank
repairing or
disassembly, ground
the airplane
to
a
suitable
ground stake.
b.
Residual
fuel
draining
from
lines
and
hoses
constitutes
a
fire
hazard. Use
caution
to prevent
the
accumulation
of
fuel
when
lines
or hoses
are
disconnected.
c.
Throughout
the
fuel
system
use
a
thread
lubricant
of
graphite-petrolatum
(Spec.
MIL-T-5544,
or
equivalent)
only
if
necessary.
Anti-seize
compound
(Spec. JAN-A-660,
or
equivalent)
may
be
used
to
seal
a
leaking
connection.
Apply
sparingly
to
male
fittings only,
omitting
the first
two
threads.
Always
be
sure that
a
compound,
the
residue
from
a
previously
use
compound,
or any
other
foreign
material
cannot enter
the
fuel system.
11-3
TROUBLE
SHOOTING.
NOTE:
Use
this chart
in
conjunction
with
the
engine
and
fuel injection
trouble
shooting
charts
in
Section
10.
PROBABLE
CAUSE
ISOLATION
PROCEDURE
NO
FUEL
FLOW
TO ENGINE-DRIVEN
PUMP.
Selector
valve
not
turned
on.
Fuel
tanks
empty.
Fuel
line
disconnected
or
broken.
Selector
valve
not
rigged
properly.
Fuel
cell
outlet screens
plugged.
Unserviceable
selector
valve.
Plugged
fuel
strainer.
Unserviceable
bypass
valve
in
electric
fuel
pump.
Fuel line
plugged.
Check
position
of
selector
valve.
Check
fuel
quantity.
Inspect
fuel
lines.
Check
selector
valve
is
in
detent.
Disconnect
fuel
lines
from
auxiliary
or
sump
tank
outlets.
No
flow
indicates
plugged
screens.
Disconnect
inlet
and
outlet
lines
from
valve.
With
valve
in
detent,
fuel
should
flow
from
inlet
line
but not
through
valve.
Inspect
strainer.
Disconnect
inlet
and
outlet
lines
from
pump.
If
fuel flow
from inlet
line
but
not
through
valve,
it
is
unserviceable.
Disconnect
at
fuel
pump inlet.
No
flow
indicates plugged
line.
Turn
selector
valve
on.
Service with proper
grade
and
amount of
fuel.
Connect
or
repair
fuel
lines.
Re-rig
selector
valve.
Remove
and
clean
screens
and
flush
out
fuel
cells.
Remove
and
repair
or replace
selector
valve.
Remove
and
clean
strainer
and
screen.
Repair
pump.
Replace
bypass
valve.
Disconnect
lines
as
necessary
to
locate
obstructions,
then
clean.
FUEL
STARVATION
AFTER STARTING
Partial
fuel
flow
from the preceding
causes.
Malfunction
of
engine-driven
fuel
pump or
fuel injection
system.
Fuel
vents
plugged.
Use
the preceding
isolation procedure,
checking
for
sufficient
rate
of
flow.
Refer
to
Section
10.
Check
per
paragraphs
11-3 and
11-48.
© Cessna
Aircraft
Company
Use
the
preceding
remedies.
Refer
to
Section
10.
See
paragraphs
11-3 and
11-48.
Change
2
Jan
5/2004