Questions and Answers

  • K
    kellisanchezSep 23, 2025
    What to do if my CG DC Drives show Err41?
    • M
      Matthew EscobarSep 23, 2025
      If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
  • R
    robertgarciaAug 25, 2025
    What to do if my CG DC Drives show Err29?
    • A
      Alexandra BrockAug 25, 2025
      If your CG DC Drive displays Err29, it indicates a fault that can arise from several causes. Here's what you should check: 1. The inverter output circuit is grounded or short-circuited: Troubleshoot peripheral problems. 2. The acceleration and deceleration time is too short: Increase the acceleration time. 3. Manual torque boost or V/F curve is not appropriate: Adjust the manually torque boost or V/F curve. 4. Voltage too low: Adjust the voltage to normal range. 5. Starting the running motor: Select RPM track start or start after the motor has stopped. 6. Sudden load in the acceleration process: Cancel the sudden load. 7. Model selection of inverter power is too small: Select an inverter with a higher rating.
  • M
    morgan86Aug 25, 2025
    What to do if my CG VSX48-013-20CEB show Err02?
    • M
      morenoashleyAug 26, 2025
      If your CG DC Drives display Err02, it could be due to: * The output circuit being grounded or short-circuited: Eliminate external faults. * The deceleration time is too short: Increase the deceleration time. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during deceleration: Remove the added load. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • T
    Tracey JohnsonAug 27, 2025
    What to do if my CG VSX48-013-20CEB show Err30?
    • D
      Douglas MasonAug 27, 2025
      If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
  • L
    Laura MolinaAug 27, 2025
    What to do if my CG VSX48-013-20CEB show Err03?
    • J
      John GrayAug 27, 2025
      If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • A
    anthony66Sep 13, 2025
    What to do if my CG VSX48-013-20CEB show Err13?
    • L
      Laurie RiceSep 13, 2025
      If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
  • U
    upriceSep 12, 2025
    What to do if my CG VSX48-013-20CEB show Err18?
    • M
      Michael DanielsSep 12, 2025
      If your CG DC Drives display Err18, it could be due to: * The PC is not working properly: Check the PC Connection. * The communication line is not normal: Check the communication cable. * H0 set communication parameters set incorrectly: The communication parameters are set correctly.
  • G
    George ColemanSep 12, 2025
    What to do if my CG VSX48-013-20CEB show Err23?
    • M
      Mr. Andrew RosarioSep 12, 2025
      If your CG DC Drives are showing Err23, it could be because: * The brake line failure or damage the brake pipe: Check the brake unit, replace the brake pipe. * An external braking resistor is too small: Increase the braking resistor.
  • D
    Don GuerreroSep 4, 2025
    What to do if my CG VSX48-013-20CEB DC Drives show Err39?
    • K
      Kathleen KingSep 4, 2025
      If your CG DC Drive displays Err39, consider these possible causes: 1. PTC sensor configuration not right: Reset PTC sensor parameter. 2. Motor temperature protection value too small: Increase motor temperature protection value. 3. Motor temperature too high: Wait until the motor is cooled.
  • M
    Melanie WalshSep 2, 2025
    What to do if my CG VSX48-013-20CEB show Err14?
    • B
      Bradley ChavezSep 2, 2025
      If your CG DC Drives display Err14, it might be due to: * The ambient temperature is too high: Lower the ambient temperature. * The air filter is blocked: Clean the air filter. * The fan is damaged: Replace the damaged fan. * The thermally sensitive resistor of the module is damaged: Replace the damaged thermally sensitive resistor. * The inverter module is damaged: Replace the inverter module.

Summary

Chapter 1 Safety Precautions

1.1 Safety Considerations

Considerations for safe installation and operation of the product.

1.2 Precautions

Detailed safety precautions for motor insulation, thermal protection, vibrations, etc.

Chapter 3 Installation and Wiring

3.5 Wiring Way of VS Series

Wiring diagrams for VSS, VSM, VSR, and VSX series inverters.

Chapter 4 Operation and display

4.3 Motor Auto-tuning

Procedure and indicators for motor auto-tuning process.

Chapter 6 Specification of Parameters

Group b0 Frequency Command

Parameters for setting frequency sources, digital settings, and limits.

Group b1 Start;Stop Control

Parameters for controlling run command, direction, start modes, and braking.

Group b2 Accel;Decel Parameters

Parameters for acceleration, deceleration times, curves, and switchover points.

Group C0 Digital Input

Configuration of digital input terminals, including functions, logic, and filtering.

Group C1 Digital Output

Configuration of digital output terminals, including functions, delay times, and enabled states.

Group C2 Analog and Pulse Input

Parameters for analog and pulse input curves, filtering, and settings.

Group C3 Analog and Pulse Output

Parameters for analog and pulse output functions, offsets, gains, and filtering.

Group d0 Parameters of Motor 1

Motor parameters for type selection, power rating, voltage, current, and auto-tuning.

Group d1 V;f Control Parameters of Motor 1

V/f curve settings, torque boost, and voltage/frequency relationships for motor control.

Group d2 Vector Control Parameters of Motor 1

Parameters for speed/torque control, ASR gains, switching frequencies, and excitation.

Group E0 Protection Parameters

Parameters for current limits, overvoltage protection, and fault actions.

Group F0 Process PID

Parameters for PID control settings, feedback sources, gains, and limits.

Chapter 7 Solar Commissioning

7.1 Parameters Description

Description of parameters for PV pump inverter control, including Vmpp and weak light settings.

Chapter 8 Elevator Commissioning

8.1 Parameters Description

Description of parameters for elevator operation, including brake control and floor functions.

Chapter 9 Maintenance and Troubleshooting

CG VSX48-013-20CEB Specifications

General IconGeneral
BrandCG
ModelVSX48-013-20CEB
CategoryDC Drives
LanguageEnglish

Related product manuals