Questions and Answers

  • R
    randolphmichaelSep 23, 2025
    What to do if my CG DC Drives show Err41?
    • J
      Jane WatsonSep 23, 2025
      If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
  • M
    Michael StanleyAug 25, 2025
    What to do if my CG VSM48-004-20CEB DC Drives show Err29?
    • T
      Tracey MclaughlinAug 25, 2025
      If your CG DC Drive displays Err29, it indicates a fault that can arise from several causes. Here's what you should check: 1. The inverter output circuit is grounded or short-circuited: Troubleshoot peripheral problems. 2. The acceleration and deceleration time is too short: Increase the acceleration time. 3. Manual torque boost or V/F curve is not appropriate: Adjust the manually torque boost or V/F curve. 4. Voltage too low: Adjust the voltage to normal range. 5. Starting the running motor: Select RPM track start or start after the motor has stopped. 6. Sudden load in the acceleration process: Cancel the sudden load. 7. Model selection of inverter power is too small: Select an inverter with a higher rating.
  • T
    Timothy TranAug 25, 2025
    What to do if my CG VSM48-004-20CEB show Err02?
    • H
      Hayden McguireAug 26, 2025
      If your CG DC Drives display Err02, it could be due to: * The output circuit being grounded or short-circuited: Eliminate external faults. * The deceleration time is too short: Increase the deceleration time. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during deceleration: Remove the added load. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • D
    Douglas PonceAug 27, 2025
    What to do if my CG VSM48-004-20CEB DC Drives show Err30?
    • M
      Michelle CurryAug 27, 2025
      If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
  • L
    latashajenningsAug 27, 2025
    What to do if my CG DC Drives show Err03?
    • C
      Curtis ArnoldAug 27, 2025
      If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • J
    johnsonmichaelSep 13, 2025
    What to do if my CG VSM48-004-20CEB show Err13?
    • M
      Meagan RyanSep 14, 2025
      If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
  • J
    jessica79Sep 12, 2025
    What to do if my CG DC Drives show Err18?
    • L
      Lauren JuarezSep 12, 2025
      If your CG DC Drives display Err18, it could be due to: * The PC is not working properly: Check the PC Connection. * The communication line is not normal: Check the communication cable. * H0 set communication parameters set incorrectly: The communication parameters are set correctly.
  • L
    Lori GordonSep 12, 2025
    What to do if my CG VSM48-004-20CEB DC Drives show Err23?
    • E
      Erik ReevesSep 12, 2025
      If your CG DC Drives are showing Err23, it could be because: * The brake line failure or damage the brake pipe: Check the brake unit, replace the brake pipe. * An external braking resistor is too small: Increase the braking resistor.
  • J
    Jordan JohnsonSep 4, 2025
    What to do if my CG VSM48-004-20CEB DC Drives show Err39?
    • H
      harrislucasSep 4, 2025
      If your CG DC Drive displays Err39, consider these possible causes: 1. PTC sensor configuration not right: Reset PTC sensor parameter. 2. Motor temperature protection value too small: Increase motor temperature protection value. 3. Motor temperature too high: Wait until the motor is cooled.
  • W
    Wendy ParkerSep 2, 2025
    What to do if my CG VSM48-004-20CEB DC Drives show Err14?
    • T
      Tiffany TaylorSep 2, 2025
      If your CG DC Drives display Err14, it might be due to: * The ambient temperature is too high: Lower the ambient temperature. * The air filter is blocked: Clean the air filter. * The fan is damaged: Replace the damaged fan. * The thermally sensitive resistor of the module is damaged: Replace the damaged thermally sensitive resistor. * The inverter module is damaged: Replace the inverter module.

Summary

Safety Precautions

Safety Considerations

Essential safety guidelines before, during, and after installation of the inverter.

General Precautions

Specific precautions for motor, installation, wiring, operation, and maintenance.

Product Information

Technical Features

Overview of the technical specifications and capabilities of the general drive.

Installation and Wiring

Terminal Configuration

Details the main and control circuit terminals for various VSX, VSM, VSS, and VSR models.

Operation and Display

Parameter Specification

Protection Parameters (Group E0)

Parameters related to overcurrent, overvoltage, and other protection functions.

Maintenance and Troubleshooting

Inspection Procedures

Guidelines for daily and regular inspections to ensure inverter longevity and performance.

CG VSM48-004-20CEB Specifications

General IconGeneral
CategoryDC Drives
ModelCG VSM48-004-20CEB
Output Current4 A
Enclosure RatingIP20
Cooling MethodFan Cooling
Input Voltage480V AC