Questions and Answers

  • E
    Erin SmithSep 23, 2025
    What to do if my CG DC Drives show Err41?
    • R
      Rachael WangSep 23, 2025
      If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
  • K
    Katie DavisAug 25, 2025
    What to do if my CG VSR239p5 DC Drives show Err29?
    • E
      ericaayalaAug 25, 2025
      If your CG DC Drive displays Err29, it indicates a fault that can arise from several causes. Here's what you should check: 1. The inverter output circuit is grounded or short-circuited: Troubleshoot peripheral problems. 2. The acceleration and deceleration time is too short: Increase the acceleration time. 3. Manual torque boost or V/F curve is not appropriate: Adjust the manually torque boost or V/F curve. 4. Voltage too low: Adjust the voltage to normal range. 5. Starting the running motor: Select RPM track start or start after the motor has stopped. 6. Sudden load in the acceleration process: Cancel the sudden load. 7. Model selection of inverter power is too small: Select an inverter with a higher rating.
  • M
    Michael HernandezAug 25, 2025
    What to do if my CG VSR239p5 show Err02?
    • B
      berryjaimeAug 26, 2025
      If your CG DC Drives display Err02, it could be due to: * The output circuit being grounded or short-circuited: Eliminate external faults. * The deceleration time is too short: Increase the deceleration time. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during deceleration: Remove the added load. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • T
    Tanner BurtonAug 27, 2025
    What to do if my CG VSR239p5 show Err30?
    • N
      ncampbellAug 27, 2025
      If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
  • N
    Nathaniel FowlerAug 27, 2025
    What to do if my CG VSR239p5 DC Drives show Err03?
    • S
      Stacy WhiteAug 27, 2025
      If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • T
    Theresa DavidsonSep 13, 2025
    What to do if my CG VSR239p5 show Err13?
    • M
      Matthew OwensSep 14, 2025
      If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
  • A
    Alyssa SalasSep 12, 2025
    What to do if my CG VSR239p5 DC Drives show Err18?
    • T
      teresa95Sep 12, 2025
      If your CG DC Drives display Err18, it could be due to: * The PC is not working properly: Check the PC Connection. * The communication line is not normal: Check the communication cable. * H0 set communication parameters set incorrectly: The communication parameters are set correctly.
  • S
    sheltonreneeSep 12, 2025
    What to do if my CG VSR239p5 DC Drives show Err23?
    • C
      Catherine HamptonSep 12, 2025
      If your CG DC Drives are showing Err23, it could be because: * The brake line failure or damage the brake pipe: Check the brake unit, replace the brake pipe. * An external braking resistor is too small: Increase the braking resistor.
  • S
    Samantha GutierrezSep 4, 2025
    What to do if my CG DC Drives show Err39?
    • K
      Kevin AllenSep 4, 2025
      If your CG DC Drive displays Err39, consider these possible causes: 1. PTC sensor configuration not right: Reset PTC sensor parameter. 2. Motor temperature protection value too small: Increase motor temperature protection value. 3. Motor temperature too high: Wait until the motor is cooled.
  • A
    Adam GarciaSep 2, 2025
    What to do if my CG DC Drives show Err14?
    • B
      Brittney SmithSep 2, 2025
      If your CG DC Drives display Err14, it might be due to: * The ambient temperature is too high: Lower the ambient temperature. * The air filter is blocked: Clean the air filter. * The fan is damaged: Replace the damaged fan. * The thermally sensitive resistor of the module is damaged: Replace the damaged thermally sensitive resistor. * The inverter module is damaged: Replace the inverter module.

Summary

Chapter 1 Safety Precautions

1.1 Safety Considerations

Essential safety guidelines for using the inverter, covering installation and handling precautions.

1.2 Precautions

Detailed warnings and precautions for motor insulation, thermal protection, vibrations, and electrical safety.

Chapter 3 Installation and Wiring

3.5 Wiring Way of VS Series

Diagrams and descriptions for connecting power and control circuits for various VS series models.

3.6 Terminal Configuration

Detailed breakdown of main and control circuit terminals for different VSX, VSM, VSS, and VSR models.

Chapter 4 Operation and Display

4.1 Introduction of LCD Keypad

Overview of the LCD keypad's appearance, keys, indicators, and parameter setting procedures.

4.2 Introduction of LED Keypad

Explanation of the LED keypad's layout, keys, indicators, and operational functions.

Chapter 5 List of Parameter

5.2 Standard Function Parameters

A detailed list of standard function parameters, their ranges, defaults, and attributes.

Chapter 6 Specification of Parameters

Group b0 Frequency Command

Parameters for controlling the frequency command source and setting operational frequencies.

Group b1 Start;Stop Control Start;Stop Control

Parameters for managing the inverter's start, stop, and running direction control.

Group b2 Accel;Decel Parameters

Parameters for configuring acceleration and deceleration times and curves for motor control.

Group C0 Digital Input

Configuration of digital input terminals for various control functions and signal logic.

Group C1 Digital Output

Definition of functions for digital output terminals like Y1, Y2, and relay outputs.

Group C2 Analog and Pulse Input

Configuration of analog and pulse input terminals, including curve settings and filtering.

Chapter 7 Solar Commissioning

Chapter 8 Elevator Commissioning

Chapter 9 Maintenance and Troubleshooting

Appendix B: Braking Resistor

CG VSR239p5 Specifications

General IconGeneral
BrandCG
ModelVSR239p5
CategoryDC Drives
LanguageEnglish

Related product manuals