Questions and Answers

  • B
    Barry RamseySep 13, 2025
    What to do if my CG DC Drives show Err13?
    • J
      johnsonjamesSep 13, 2025
      If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
  • T
    Teresa CampbellSep 23, 2025
    What to do if my CG VSM48-006-20CEB show Err41?
    • J
      John RodriguezSep 23, 2025
      If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
  • H
    hosborneSep 5, 2025
    What to do if my CG VSM48-006-20CEB show Err12?
    • A
      Angela SteeleSep 5, 2025
      If your CG DC Drives are showing Err12, check if: * The load is too heavy or locked-rotor occurs on the motor: Reduce the load and check the motor and mechanical condition. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • M
    Morgan RiceAug 27, 2025
    What to do if my CG VSM48-006-20CEB show Err30?
    • B
      byrdtinaAug 27, 2025
      If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
  • M
    Megan WarnerAug 27, 2025
    What to do if my CG VSM48-006-20CEB DC Drives show Err03?
    • R
      Robert PorterAug 27, 2025
      If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • D
    David DelgadoAug 28, 2025
    What to do if my CG VSM48-006-20CEB DC Drives show Err04?
    • M
      Mary HoltAug 28, 2025
      If you're seeing Err04 on your CG DC Drives, here's what might be happening: * The input voltage is too high: Adjust the voltage to normal range. * An external force drives the motor during acceleration: Cancel the external force or install a braking resistor. * The acceleration time is too short: Increase the acceleration time. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • B
    bcollinsAug 29, 2025
    What to do if my CG VSM48-006-20CEB show Err05?
    • L
      Laura SuarezAug 29, 2025
      If your CG DC Drives are showing Err05, consider these potential causes: * The input voltage is too high: Adjust the voltage to normal range. * An external force drives the motor during deceleration: Cancel the external force or install the braking resistor. * The deceleration time is too short: Increase the deceleration time. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • D
    Derek StephensSep 16, 2025
    What to do if my CG DC Drives show Err16?
    • G
      Greg ChristensenSep 16, 2025
      If your CG DC Drives display Err16, press the STOP / RST key to reset.
  • T
    Traci SullivanSep 15, 2025
    What to do if my CG VSM48-006-20CEB DC Drives show Err15?
    • M
      Marco FergusonSep 15, 2025
      If your CG DC Drives display Err15, it means the EEPROM chip is damaged. Replace the main control board.
  • M
    Monica CaseSep 6, 2025
    What to do if my CG VSM48-006-20CEB DC Drives show Err07?
    • B
      Brandon CainSep 7, 2025
      If your CG DC Drives display Err07, it could be due to: * Instantaneous power failure occurs on the input power supply: Reset the fault. * The AC drive's input voltage is not within the allowable range: Adjust the voltage to normal range. * The bus voltage is abnormal: Contact the agent or CG.

Summary

Emotron VS Series Drive

Chapter 1 Safety Precautions

Safety Considerations

Guidance on safe practices during installation and before operation phases.

Chapter 3 Installation and Wiring

Wiring Way of VS Series

Provides wiring diagrams for VSS, VSM, VSR, and VSX series drives.

Chapter 4 Operation and display

Chapter 5 List of Parameter

Standard Function Parameters

Lists and describes standard parameters grouped by category.

Chapter 6 Specification of Parameters

Group A0 System Parameters

Details system parameters including password, display, and initialization settings.

Group b0 Frequency Command

Parameters related to setting and controlling the frequency command source.

Group b1 Start;Stop Control

Parameters for controlling the start, stop, and direction of the motor.

Group b2 Accel;Decel Parameters

Settings for acceleration and deceleration times and curves.

Group C0 Digital Input

Configuration of digital input terminals and their functions.

Group C1 Digital Output

Configuration of digital output terminals and their functions.

Group C2 Analog and Pulse Input

Parameters for configuring analog and pulse input signals.

Group C3 Analog and Pulse Output

Parameters for configuring analog and pulse output signals.

Group d0 Parameters of Motor 1

Motor parameters for Motor 1, including type, rating, and electrical properties.

Group d1 V;f Control Parameters of Motor 1

V/f control parameters for Motor 1, including curve settings and torque boost.

Group d2 Vector Control Parameters of Motor 1

Vector control parameters for Motor 1, including speed/torque control and PI settings.

Group E0 Protection Parameters

Parameters for various protection functions like current limit and overvoltage.

Group F0 Process PID

Parameters for configuring the Process PID control.

Group U0 Status Monitoring

Parameters for monitoring the AC drive's running status.

Group U1 Fault Record

Records of past faults, including code, frequency, current, and bus voltage.

Chapter 8 Elevator Commissioning

Chapter 9 Maintenance and Troubleshooting

Display Fault Name

Lists fault codes, possible causes, and solutions for troubleshooting.

Chapter 10 Maintenance and Inspection

Appendix B: Braking Resistor

CG VSM48-006-20CEB Specifications

General IconGeneral
BrandCG
ModelVSM48-006-20CEB
CategoryDC Drives
LanguageEnglish

Related product manuals