What to do if my CG DC Drives show Err13?
- JjohnsonjamesSep 13, 2025
If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
What to do if my CG DC Drives show Err13?
If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
What to do if my CG VSM48-006-20CEB show Err41?
If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
What to do if my CG VSM48-006-20CEB show Err12?
If your CG DC Drives are showing Err12, check if: * The load is too heavy or locked-rotor occurs on the motor: Reduce the load and check the motor and mechanical condition. * The AC drive model is of too small power class: Select an AC drive of higher power class.
What to do if my CG VSM48-006-20CEB show Err30?
If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
What to do if my CG VSM48-006-20CEB DC Drives show Err03?
If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
What to do if my CG VSM48-006-20CEB DC Drives show Err04?
If you're seeing Err04 on your CG DC Drives, here's what might be happening: * The input voltage is too high: Adjust the voltage to normal range. * An external force drives the motor during acceleration: Cancel the external force or install a braking resistor. * The acceleration time is too short: Increase the acceleration time. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
What to do if my CG VSM48-006-20CEB show Err05?
If your CG DC Drives are showing Err05, consider these potential causes: * The input voltage is too high: Adjust the voltage to normal range. * An external force drives the motor during deceleration: Cancel the external force or install the braking resistor. * The deceleration time is too short: Increase the deceleration time. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
What to do if my CG DC Drives show Err16?
If your CG DC Drives display Err16, press the STOP / RST key to reset.
What to do if my CG VSM48-006-20CEB DC Drives show Err15?
If your CG DC Drives display Err15, it means the EEPROM chip is damaged. Replace the main control board.
What to do if my CG VSM48-006-20CEB DC Drives show Err07?
If your CG DC Drives display Err07, it could be due to: * Instantaneous power failure occurs on the input power supply: Reset the fault. * The AC drive's input voltage is not within the allowable range: Adjust the voltage to normal range. * The bus voltage is abnormal: Contact the agent or CG.
Guidance on safe practices during installation and before operation phases.
Provides wiring diagrams for VSS, VSM, VSR, and VSX series drives.
Lists and describes standard parameters grouped by category.
Details system parameters including password, display, and initialization settings.
Parameters related to setting and controlling the frequency command source.
Parameters for controlling the start, stop, and direction of the motor.
Settings for acceleration and deceleration times and curves.
Configuration of digital input terminals and their functions.
Configuration of digital output terminals and their functions.
Parameters for configuring analog and pulse input signals.
Parameters for configuring analog and pulse output signals.
Motor parameters for Motor 1, including type, rating, and electrical properties.
V/f control parameters for Motor 1, including curve settings and torque boost.
Vector control parameters for Motor 1, including speed/torque control and PI settings.
Parameters for various protection functions like current limit and overvoltage.
Parameters for configuring the Process PID control.
Parameters for monitoring the AC drive's running status.
Records of past faults, including code, frequency, current, and bus voltage.
Lists fault codes, possible causes, and solutions for troubleshooting.