    What to do if my CG DC Drives show Err41?
    • C
      Christina SmithSep 23, 2025
      If your CG DC Drive displays Err41, and E0.18 = 00100, it means that the current output amp is more than E0.19. Check the current load.
  • Y
    yperkinsAug 25, 2025
    What to do if my CG VSM48-009-20CEB show Err29?
    • E
      erica32Aug 25, 2025
      If your CG DC Drive displays Err29, it indicates a fault that can arise from several causes. Here's what you should check: 1. The inverter output circuit is grounded or short-circuited: Troubleshoot peripheral problems. 2. The acceleration and deceleration time is too short: Increase the acceleration time. 3. Manual torque boost or V/F curve is not appropriate: Adjust the manually torque boost or V/F curve. 4. Voltage too low: Adjust the voltage to normal range. 5. Starting the running motor: Select RPM track start or start after the motor has stopped. 6. Sudden load in the acceleration process: Cancel the sudden load. 7. Model selection of inverter power is too small: Select an inverter with a higher rating.
  • V
    Virginia BartlettAug 25, 2025
    What to do if my CG VSM48-009-20CEB show Err02?
    • R
      randallcandiceAug 26, 2025
      If your CG DC Drives display Err02, it could be due to: * The output circuit being grounded or short-circuited: Eliminate external faults. * The deceleration time is too short: Increase the deceleration time. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during deceleration: Remove the added load. * The braking unit and braking resistor are not installed: Install the braking unit and braking resistor.
  • A
    Andrew SimonAug 27, 2025
    What to do if my CG VSM48-009-20CEB show Err30?
    • C
      Cynthia MitchellAug 27, 2025
      If your CG DC Drive shows Err30, consider the following potential causes and solutions: 1. Input voltage is too high: Adjust the voltage to the normal range. 2. There is external force dragging the motor to run in the deceleration process: Cancel external force or install a brake resistor. 3. The deceleration time is too short: Increase the deceleration time. 4. No installation of braking resistor: Install braking resistor.
  • D
    Derek CampbellAug 27, 2025
    What to do if my CG VSM48-009-20CEB DC Drives show Err03?
    • G
      gharringtonAug 27, 2025
      If your CG DC Drives display Err03, it may be caused by: * The output circuit being grounded or short-circuited: Eliminate external faults. * The voltage is too low: Adjust the voltage to normal range. * A sudden load is added during operation: Remove the added load. * The AC drive model is of too small power class: Select an AC drive of higher power class.
  • D
    Dylan BrownSep 13, 2025
    What to do if my CG VSM48-009-20CEB DC Drives show Err13?
    • J
      Jennifer BrewerSep 13, 2025
      If your CG DC Drives display Err13, it indicates that an external fault signal is input via DI. Reset the operation.
  • M
    Michael WalkerSep 12, 2025
    What to do if my CG DC Drives show Err18?
    • J
      Jonathan RileySep 12, 2025
      If your CG DC Drives display Err18, it could be due to: * The PC is not working properly: Check the PC Connection. * The communication line is not normal: Check the communication cable. * H0 set communication parameters set incorrectly: The communication parameters are set correctly.
  • A
    Amber StaffordSep 12, 2025
    What to do if my CG DC Drives show Err23?
    • T
      Travis ValdezSep 12, 2025
      If your CG DC Drives are showing Err23, it could be because: * The brake line failure or damage the brake pipe: Check the brake unit, replace the brake pipe. * An external braking resistor is too small: Increase the braking resistor.
  • Z
    Zachary JohnsonSep 4, 2025
    What to do if my CG DC Drives show Err39?
    • H
      hsmithSep 4, 2025
      If your CG DC Drive displays Err39, consider these possible causes: 1. PTC sensor configuration not right: Reset PTC sensor parameter. 2. Motor temperature protection value too small: Increase motor temperature protection value. 3. Motor temperature too high: Wait until the motor is cooled.
  • C
    Christopher MccarthySep 2, 2025
    What to do if my CG VSM48-009-20CEB DC Drives show Err14?
    • L
      Lucas AyalaSep 2, 2025
      If your CG DC Drives display Err14, it might be due to: * The ambient temperature is too high: Lower the ambient temperature. * The air filter is blocked: Clean the air filter. * The fan is damaged: Replace the damaged fan. * The thermally sensitive resistor of the module is damaged: Replace the damaged thermally sensitive resistor. * The inverter module is damaged: Replace the inverter module.

Summary

Emotron VS Series Drive

Chapter 1 Safety Precautions

Safety Considerations and Precautions

Covers general safety considerations and specific precautions for inverter use.

Chapter 2 Product Information

Installation Environment and Direction

Details installation site requirements, orientation, space, and cooling.

Mounting, Peripherals, and Wiring

Covers fixed mounting, peripheral devices, wiring diagrams, terminal configuration, and EMI.

Chapter 3 Installation and Wiring

Keypad Operation and Settings

Explains LCD/LED keypads, motor auto-tuning, password, and keypad lock functions.

Chapter 4 Operation and Display

Chapter 5 List of Parameter

System, Frequency Command, Start;Stop, and Accel;Decel Parameters

Details parameters for system settings, frequency command, start/stop control, and accel/decel.

Chapter 6 Specification of Parameters

Motor Type Selection and Parameters

Covers motor type selection, basic parameters, and asynchronous/PMSM motor details.

V;f Curve, Torque Boost, and Multi-point Settings

Configures V/f curves, torque boost, and multi-point V/f settings for Motor 1.

Current Limit, Overvoltage, and Protection Actions

Details parameters for current limit, overvoltage stall, protection actions, and overload alarms.

Fault History and Information

Displays codes and details for the latest, previous, and before-previous faults.

Frequency Command (B0)

Covers parameters for selecting and setting frequency sources and commands.

Fault Codes, Causes, and Solutions

Lists common fault codes, their possible causes, and recommended solutions for troubleshooting.

Inspection Procedures and Component Life

Outlines daily and regular inspection routines, component maintenance, and life cycles.

CG VSM48-009-20CEB Specifications

General IconGeneral
BrandCG
ModelVSM48-009-20CEB
CategoryDC Drives
LanguageEnglish

Related product manuals