EasyManua.ls Logo

Chacon 54311 - Adjusting Temperature Setpoints

Chacon 54311
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3. Review and adjust the set-temp
Comfortable mode icon is , while Economic mode icon is .
At the normal operation mode, the control temperature could be set.
1. Press and hold
or (for less than 2 seconds) to view the current set-point temperature.
The example shows Econ set-temp is 19.0
0
C. Release the key will return to normal mode.
2. Continue to hold the key for 2 seconds until the set-point temperature flash to adjust the
control temperature.
3. Press
or again to increase or decrease the temperature setting.
4. Hold or button to enter fast advances adjustment.
5. Press COMF/ECON to toggle between Comfort and Econ set-temp. The Temperature mode
indicator changes accordingly.
6. For heat mode, press and hold COMF/ECON for 1.5 seconds will change to Defrost set-temp.
Defrost set-temp is fixed at 5.0°C/41°F and is not adjustable. The temperature display will not
flash and pressing
or will not change it. This is for review only.
7. For heat mode, if Setback mode has been set beforehand, press __ will display the setback
temperature to adjust. If setback mode has not been set, the __ will not response. Setback set-
temp is initialized to Econ set-temp minus 3°C/6°F, but once it is create it is independent to the
Econ set-temp until the Setback function activates next time. Setback set-temp cannot be
higher than Econ set-temp. For cool mode, press __ doesn’t have any effect.
14

Other manuals for Chacon 54311