2. Technical Characteristics
2.1. Heating system
2.1.1. Pulse Width Modulation (PWM)
This wireless thermostat offers Pulse width modulation control that enables a set point
temperature to be maintained in a precise and convenient way. In the case of under floor heating,
the duration of opening for the valve actuator is regulated by comparing continuously the set point
temperature with the actual temperature. In this way, the room temperature can reach the set
temperature with minimal temperature deviation. Subsequently, the room temperature is
constantly maintained via the PWM control. In the case of the thermostat is used with radiator or
convector heating system, PWM can be switched off if necessary.
2.1.2. Setback Temperature
This wireless thermostat has setback temperature function. Once the setback button is activated,
the set point temperature is 3
0
C or 6
0
F lower than the Econ set-temp. For example, if the Econ
set-temp is at 22
0
C, then the setback temperature is 19
0
C.
Press __ button to toggle between normal set-temperature and setback function, icon will
flash and animate to indicate that the setback function is activated.