Default of Comfort, Econ and Setback:
If System option is set to Heat:
Comfort: 21.0°C (70°F)
Econ: 19.0°C (66°F)
Setback: = Econ – 3°C (6°F) = 16.0°C (60°F)
If System option is set to Cool:
Comfort: 24.0°C (75°F)
Econ: 27°C (81°F)
Function Hard reset Soft reset
Operation mode Normal mode
Temperature scale Depends on option switch
Room temperature The current room temperature
Set-temp Base on the current time and program
Preset Set-temps Default Retrieved from EEPROM
Clock 00:00 Retrieved from EEPROM
Day Monday Retrieved from EEPROM
Program day 5 –2 or 7 – days depends on Program day option
Program profile Reset to default (Refer to 5.1.3) Retrieved from EEPROM
Program All days are reset to Program 1 Retrieved from EEPROM
Program override All cleared
System Heat or Cool mode depends on System option
Control mode On – Off or PWM control depends on Control mode option
3