EasyManua.ls Logo

Chaffoteaux & Maury Mira System CF - 18. Technical specifications

Chaffoteaux & Maury Mira System CF
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
These boilers are designed to operate with natural gas or LPG. If the type of gas is changed, only a qualified professional is
authorised to carry out this operation.
18. Technical specifications
Model 24 kW CF
Heating power Pn
7,5 - 24 KW
Variable tank pre-heating power Pn max
24 kW
Class I - type B11BS (natural draught/chimney/overflow safety device)
Category II 2E+3+
Fresh air flow rate required for combustion V 48 m
3
h.
Combustion products mass flow rate M 20 g/s
Average temperature for combustion products 120 °C
Associated BACD tank capacity 120 150
Specific domestic hot water flow rate (ΔT: 30 K) D 22,2 l/mn 24,6 l/mn
Minimum central heating circuit flow rate 300 I/h.
Maximum heating circuit pressure Pw max
3 bar
Adjustable heating flow temperature 35 to 85 °C
Adjustable domestic hot water temperature (system plus) 40 to 60 °C
Electric voltage 230 volt, single phase - 50 Hz
Electrical power consumption 90 W
Electrical protection IP X4D
Nominal gas flow rate (15 °C-1013 mbar) Gas rate max Gas rate mini
Qn 26,0 kW 9 kW
G 20 34,02 MJ/m
3
at 20 mbar Vr 2,75 m
3
/h 0,95 m
3
/h
G 30 45,6 MJ/kg a 28-30 mbar Vr 2,05 kg/h 0,71 kg/h
G 31 46,4 MJ/kg at 37 mbar Vr 2,02 kg/h 0,70 kg/h
Nat Prop
Feeder marking Marking NAT Gas 125 LPG Gas 77
Injector size in 1/100 of mm 125 77
No. of injectors 12 12