7698967.01 (1-01/18) 44
INSTALLER Section (en)
21. TECHNICAL PARAMETERS
CHAPPEE INITIA+ DUO
3.25 HTE 3.33 HTE
Condensing boiler
Yes Yes
Low-temperature boiler
(1)
No No
B1 boiler
No No
Cogeneration space heater
No No
Combination heater
Yes Yes
Rated heat output
Prated
kW 16 24
Useful heat output at rated heat output
and high temperature regime
(2)
P
4
kW 16.0 24.0
Useful heat output at 30% of rated heat
output and low temperature regime
(1)
P
1
kW 5.3 8.0
Seasonal space heating energy efficiency
ƞ
s
% 93 93
Useful efficiency at rated heat output and
high temperature regime
(2)
ƞ
4
% 88.0 88.0
Useful efficiency at 30% of rated heat
output and low temperature regime
(1)
ƞ
1
% 98.0 98.1
Auxiliary electricity consumption
Full load
elmax
kW 0.025 0.030
Part load
elmin
kW 0.014 0.014
Standby mode
P
SB
kW 0.003 0.003
Other items
Standby heat loss
P
stby
kW 0.060 0.050
Ignition burner power consumption
P
ign
kW 0.000 0.000
Annual energy consumption
Q
HE
GJ
50 74
Sound power level, indoors
L
WA
dB 51 53
Emissions of nitrogen oxides
NO
X
mg/kWh 19 22
Domestic hot water parameters
Declared load profile
XL XL
Daily electricity consumption
Q
elec
kWh 0.130 0.135
Annual electricity consumption
AEC
kWh 29 30
Water heating energy efficiency
ƞ
wh
% 81 81
Daily fuel consumption
Q
fuel
kWh 24.290 24.580
Annual fuel consumption
AFC
GJ 18 18
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.