13. Electrical System
Connect the power to the electrical system, make sure that the voltages and frequency
available on site match the power requirements of the machine.
Connect the power cable to the main power switch and make sure that the machine is
correctly grounded.
When viewed from the pulley side, the main motor must run in a clockwise direction (the
spindle must run in a counter-clockwise direction). If you have a 3 phase machine, two of the
phases can be changed if the spindle runs clockwise. Make sure that the power has been
disconnected at the main power supply before changing the phases.