AC Voltage | 120V |
---|---|
Fuel Type | Gasoline |
Frequency | 60 Hz |
Running Watts | 1, 600 watts |
Output Power | 1, 600 watts |
Peak Power | 900 W |
Waveform | Sine Wave |
USB Port | Yes |
Protections | Overload |
Follow basic safety precautions to reduce risk of injury and equipment damage.
Place the Power Inverter on a flat surface ensuring adequate ventilation and secure fastening.
Connect the recommended battery cables to the inverter's positive and negative terminals.
Attach the ground cable to the appropriate location based on the mounting environment.
Plug 115 VAC devices into the AC receptacles, ensuring total wattage does not exceed 1,000 watts.
Flip the power switch to ON; the switch illumination indicates power.
After use, disconnect appliances and flip the switch to the OFF position.
Keep unit clean and dry; servicing must be done by a qualified technician.
Indicates low input voltage; recharge the battery to avoid automatic shutdown.
Calculate required amps by dividing load watts by 12V input voltage.
Some appliances, like TVs, may need 2-6 times their wattage to start.
Caused by modified sine wave; use systems with higher quality power supplies.
Minimize by positioning inverter away from antenna and cables, use shielded cables.
Reduce load or ensure input voltage stays above 10.5V to maintain power flow.
Check switch, device wattage, and thermal shutdown; ensure adequate ventilation.