Fig. 10: the indoor PCB
Note:the above parameter is tested when there is the power in the PCB, so is the following 。
The voltage of the cross
flow fan feedback end will
be increased gradually from
0 to +2.4VDC when turning
on the indoor unit .
PTC1 resistance
value:1.02KΩ
(25℃)
The limited current resistance
value:14.8 kΩ 。
The voltage stabilizing diode
ZD1 、ZD2 reference value :
Forward resistance : 713Ω
reverse resistance: ∞
PTC1 resistance value:
1.02KΩ(25℃)
The limited current
resistance value R54 :
0.76kΩ , R58: 2 kΩ
The voltage stabilizing diode
ZD1 、ZD2 reference value:
Forward resistance : 713 Ω
reverse resistance :∞
Please test the DC motor end to N terminal voltage value:
VCC-N:+15VDC,P-N: +340VDC,Vsp -N :0~+5VDC