R410A50Hz Universal Outdoor Series Technical Manual Outdoor Unit
I
GD Chigo Heating & Ventilation Equipment Co., Ltd.
R410A 50Hz Universal Outdoor Series
Technical Manual
LCAC/6.0/201908

Questions and Answers

  • J
    Jesus HessSep 23, 2025
    What to do if my Chigo CCA-48HR1 Air Conditioner has condenser pipe temperature sensor (T3) failure?
    • T
      tina71Sep 23, 2025
      If your Chigo Air Conditioner displays a condenser pipe temperature sensor (T3) failure, check the condenser pipe temperature sensor and replace it if necessary.
  • J
    Jamie JimenezAug 25, 2025
    What to do if the remote control signal is not transmitted even when the ON/OFF button of Chigo CCA-48HR1 Air Conditioner is pushed?
    • S
      Sandy LaneAug 25, 2025
      If the remote control signal of your Chigo Air Conditioner is not transmitted even when the ON/OFF button is pushed, it could be due to exhausted batteries in the remote controller. Replace the batteries, as the remote control won't transmit a signal if the power supply is off.
  • J
    Jared WyattAug 25, 2025
    Why TEMP. Indicator does not come on Chigo CCA-48HR1?
    • C
      Christine DixonAug 26, 2025
      The temperature indicator on your Chigo Air Conditioner won't appear if the MODE is set to 'FAN ONLY'. You cannot set the temperature during fan-only operation.
  • H
    Holly MilesAug 26, 2025
    Why does the indication on the display disappears after a lapse of time on Chigo Air Conditioner?
    • W
      Wesley MaddenAug 27, 2025
      If the indication on the display of your Chigo Air Conditioner disappears after some time, it may be because the timer operation has ended when the OFF TIMER is indicated on the display. The air conditioner stops when the set time has elapsed.
  • J
    Jennifer RodgersSep 23, 2025
    What to do if my Chigo CCA-48HR1 Air Conditioner has indoor unit EEPROM failure?
    • B
      Beth RoweSep 23, 2025
      If your Chigo Air Conditioner indicates an indoor unit EEPROM failure, replace the indoor unit EEPROM.
  • E
    Eduardo NelsonSep 13, 2025
    What to do if my Chigo CCA-48HR1 Air Conditioner outdoor unit has over-current protection?
    • X
      xellisSep 13, 2025
      If your Chigo Air Conditioner's outdoor unit is experiencing over-current protection, assess the outdoor unit for electrical issues and repair as required.
  • S
    Sandra DiazSep 12, 2025
    What to do if my Chigo CCA-48HR1 has high pressure protection?
    • A
      Austin JonesSep 12, 2025
      If your Chigo Air Conditioner is showing a high pressure protection error, check the system pressure and resolve any issues affecting those pressure levels.
  • M
    mleeSep 12, 2025
    What to do if my Chigo CCA-48HR1 has low pressure protection?
    • K
      katie77Sep 12, 2025
      If your Chigo Air Conditioner is showing a low pressure protection error, check the system pressure and resolve any issues affecting those pressure levels.
  • J
    Joann HernandezSep 4, 2025
    What does it mean when the running and timer lights are flashing on my Chigo Air Conditioner?
    • N
      Nicholas SotoSep 4, 2025
      If your Chigo Air Conditioner is experiencing an indoor unit EEPROM failure, the running light and timer light will flash.
  • M
    Michele WaltersSep 2, 2025
    What does it mean when the defrost and warning lights are flashing on my Chigo Air Conditioner?
    • C
      Cody EdwardsSep 2, 2025
      If your Chigo Air Conditioner is under outdoor protection, the defrost light and warning light will be flashing.

Summary

General Information

Nomenclature

Explains model name coding system for units.

Model Names and Appearance

Lists unit model names and illustrates external appearance.

Features

Details key features applicable to the product series.

Indoor Unit Operations

Cassette Type Indoor Units

Covers technical details for cassette indoor units.

Duct Type Indoor Units

Provides information on duct type indoor units.

Floor & Ceiling Indoor Units

Details features for floor and ceiling indoor units.

Outdoor Unit Specifications

Model Specifications

Lists detailed specifications for outdoor units.

Dimensions and Service Space

Provides dimensional drawings and installation space for outdoor units.

Wiring Diagrams and Electrical Characteristics

Illustrates wiring diagrams and presents electrical characteristics for outdoor units.

Operation Limits and Sound Levels

Specifies temperature ranges and sound levels for outdoor units.

Exploded Views and Troubleshooting

Shows unit part views and provides fault finding guidance.

Installation Procedures

Installation Precautions and Pipe Work

Offers essential precautions for safe installation and pipe connection guidance.

Vacuum Drying and Refrigerant Charging

Details procedures for vacuum drying pipes and calculating refrigerant charge.

Water Drainage and Insulation

Covers guidelines for drainpipe installation and pipe insulation.

Test Operation

Outlines the procedure for conducting test operations and verifying system functionality.

Control Systems

Wireless Remote Controller

Explains the functions and icons of the wireless remote controller.

Wired Controller

Provides instructions for using and installing the wired controller.

Chigo CCA-48HR1 Specifications

General IconGeneral
Cooling Capacity48000 BTU/h
Heating Capacity48000 BTU/h
Energy Efficiency Ratio (EER)2.8
RefrigerantR410A
Operating Temperature (Cooling)18-43°C
TypeSplit System
Power Supply220-240V, 50Hz
Noise Level (Outdoor Unit)58 dB
Operating Temperature (Heating)-7°C to 24°C