What to do if my Chigo CCA-48HR1 has high pressure protection?
- AAustin JonesSep 12, 2025
If your Chigo Air Conditioner is showing a high pressure protection error, check the system pressure and resolve any issues affecting those pressure levels.
What to do if my Chigo CCA-48HR1 has high pressure protection?
If your Chigo Air Conditioner is showing a high pressure protection error, check the system pressure and resolve any issues affecting those pressure levels.
What does it mean when the timer light is flashing on my Chigo CCA-48HR1 Air Conditioner?
If the ambient temperature sensor (T1) fails on your Chigo Air Conditioner, the timer light will flash.
What does it mean when the running light is flashing on my Chigo CCA-48HR1?
If the evaporator pipe temperature sensor (T2) fails on your Chigo Air Conditioner, the running light will flash.
What does it mean when the defrost light is flashing on my Chigo CCA-48HR1?
If the condenser pipe temperature sensor (T3) fails on your Chigo Air Conditioner, the defrost light will flash.
What to do if buttons on the Chigo Air Conditioner remote controller don’t work?
If the buttons on your Chigo Air Conditioner remote aren't working, try pressing the Reset button.
Why are the running and defrost lights flashing on my Chigo CCA-48HR1 Air Conditioner?
If there is an indoor unit and wire controller communication failure in your Chigo Air Conditioner, the running light and defrost light will flash.
What does it mean when the running and timer lights are flashing on my Chigo Air Conditioner?
If your Chigo Air Conditioner is experiencing an indoor unit EEPROM failure, the running light and timer light will flash.
Why are the defrost and timer lights flashing on my Chigo Air Conditioner?
If your Chigo Air Conditioner's indoor fan has stall protection activated, the defrost light and timer light will flash.
What does it mean when the defrost and warning lights are flashing on my Chigo Air Conditioner?
If your Chigo Air Conditioner is under outdoor protection, the defrost light and warning light will be flashing.
Why are the timer and warning lights flashing on my Chigo CCA-48HR1?
If there is an indoor and outdoor unit communication failure in your Chigo Air Conditioner, the timer light and warning light will flash.
| Cooling Capacity | 48000 BTU/h |
|---|---|
| Heating Capacity | 48000 BTU/h |
| Energy Efficiency Ratio (EER) | 2.8 |
| Refrigerant | R410A |
| Operating Temperature (Cooling) | 18-43°C |
| Type | Split System |
| Power Supply | 220-240V, 50Hz |
| Noise Level (Outdoor Unit) | 58 dB |
| Operating Temperature (Heating) | -7°C to 24°C |
Explains model name coding system for units.
Lists unit model names and illustrates external appearance.
Details key features applicable to the product series.
Covers technical details for cassette indoor units.
Provides information on duct type indoor units.
Details features for floor and ceiling indoor units.
Lists detailed specifications for outdoor units.
Provides dimensional drawings and installation space for outdoor units.
Illustrates wiring diagrams and presents electrical characteristics for outdoor units.
Specifies temperature ranges and sound levels for outdoor units.
Shows unit part views and provides fault finding guidance.
Offers essential precautions for safe installation and pipe connection guidance.
Details procedures for vacuum drying pipes and calculating refrigerant charge.
Covers guidelines for drainpipe installation and pipe insulation.
Outlines the procedure for conducting test operations and verifying system functionality.
Explains the functions and icons of the wireless remote controller.
Provides instructions for using and installing the wired controller.