  • B
    Brenda WilliamsAug 14, 2025
    What to do if red light is flashing on Chiltern Invadex WISPA 100 Plus Medical Equipment?
    • C
      carsondanielAug 14, 2025
      If the red light on your Chiltern Invadex Medical Equipment is flashing, the batteries are critically low. You should charge them immediately.
  • D
    Diana Allen MDAug 17, 2025
    Why does my Chiltern Invadex WISPA 100 Plus Medical Equipment hoist make a beeping sound?
    • R
      ralphodonnellAug 18, 2025
      If your Chiltern Invadex Medical Equipment hoist is making a beeping sound, it's likely because the battery is low or the hoist was left off charge. To resolve this, charge the batteries and return the hoist to its charging point.
  • J
    Johnathan EvansAug 21, 2025
    What does it mean if the red light is on for Chiltern Invadex WISPA 100 Plus Medical Equipment?
    • D
      Darlene ConleyAug 21, 2025
      If the red light is on for your Chiltern Invadex Medical Equipment, it indicates that the battery is low. Charge the batteries to resolve this.
  • C
    Charles ConwayAug 25, 2025
    What does it mean if the green light is on for Chiltern Invadex Medical Equipment?
    • J
      Jamie JonesAug 26, 2025
      If the green light is on for your Chiltern Invadex Medical Equipment, it means the batteries are charging. The light will turn off when charging is complete.
  • R
    Raymond LutzAug 28, 2025
    How to fix Chiltern Invadex WISPA 100 Plus Medical Equipment hoist lacking power?
    • R
      Rebecca DuncanAug 28, 2025
      If your Chiltern Invadex Medical Equipment hoist is lacking power, it is probably because the battery is low. You should charge the batteries.
  • R
    Randall WilliamsAug 31, 2025
    Why are the red and green lights flashing on my Chiltern Invadex WISPA 100 Plus Medical Equipment?
    • F
      Felicia MolinaAug 31, 2025
      If the red and green lights are flashing on your Chiltern Invadex Medical Equipment, it indicates the hoist is idle. Return it to charge.
  • C
    Christine BanksSep 3, 2025
    Why does Chiltern Invadex WISPA 100 Plus hoist lift when down button is pressed?
    • W
      walshmichaelSep 3, 2025
      If your Chiltern Invadex Medical Equipment hoist lifts when the down button is pressed, the airline may be incorrectly installed, or the lifting tape may be reversed on the spool. To correct this, ensure the black line on the handset aligns with the raised edges on the hoist connection when inserted into the grommet on the hoist box. Alternatively, press the up button to lower the carry bar while gently pulling the lift tape down to the end of its travel. The tape will then rewind itself correctly, or the lower cutout will operate. If the lower cutout operates, the tape is wound correctly.
  • T
    Terry GreenSep 7, 2025
    What does it mean if the orange light is flashing on Chiltern Invadex WISPA 100 Plus Medical Equipment?
    • S
      Sandra TuckerSep 7, 2025
      If the orange light is flashing on your Chiltern Invadex Medical Equipment, it means a service is overdue. You should arrange a service call.
  • G
    Gina PetersonSep 10, 2025
    What does it mean if the orange light is on for Chiltern Invadex WISPA 100 Plus?
    • T
      Timothy RobertsSep 10, 2025
      If the orange light is on for your Chiltern Invadex Medical Equipment, it means a service is due. You should arrange a service call.

Summary

Safety Considerations

Prior to Use

Essential checks and precautions before operating the hoist.

Using the controls

Emergency Stop & Reset Procedure

Emergency Stop

Procedure for stopping the hoist in an emergency.

Reset Procedure

Steps to reset the hoist after an emergency stop or overload.

Emergency Lowering

Servicing and maintenance

Do Not Use If

Conditions that require the hoist to be taken out of service.

Troubleshooting

Battery models only

Troubleshooting steps for battery-powered models.

Powered models only

Troubleshooting steps for powered models.

All models

Troubleshooting steps applicable to all hoist models.