EasyManua.ls Logo

CHINT NVF5-1.5/TS4-B - User Manual

CHINT NVF5-1.5/TS4-B
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Table of Contents

Other manuals for CHINT NVF5-1.5/TS4-B

Question and Answer IconNeed help?

Do you have a question about the CHINT NVF5-1.5/TS4-B and is the answer not in the manual?

CHINT NVF5-1.5/TS4-B Specifications

General IconGeneral
ModelNVF5-1.5/TS4-B
Rated Power1.5 kW
Output Power1.5 kW
Frequency50/60 Hz
Protection LevelIP20
Humidity5% to 95% (non-condensing)
Cooling MethodForced Air Cooling

Summary

Chapter 1 Safety Information

Safety Precautions Before Installation

Advises against installing damaged inverters and touching terminals directly.

Safety Precautions During Installation

Highlights dangers of electric shock and fire during installation.

Safety Precautions During Wiring

Details safe wiring practices to prevent electric shock and equipment damage.

Safety Precautions During Running

Provides safety guidelines for operating the inverter.

Chapter 2 Product Overview

Technical Specifications

Provides detailed technical data including input, output, and control functions.

Chapter 3 Installation and Wiring

Chapter 4 Integral Keypad

Chapter 5 Simple Parameter Menu and Commissioning Process

Simple Commissioning Process

Provides a step-by-step guide for basic inverter commissioning.

Chapter 6 Parameter Function Description

Frequency Reference Setting

Details how to set the main frequency reference from various sources.

Start and Stop Setting

Configures inverter start modes and stop modes.

Motor Auto Tuning

Explains the process of automatically tuning motor parameters.

Vector Control Parameters

Details parameters for vector control modes, including speed and torque.

Chapter 7 Troubleshooting

Diagnostic Process

Provides a flowchart for diagnosing inverter faults.

Fault Description and Troubleshooting

Lists common fault codes, reasons, and corrective actions.

Chapter 8 Maintenance

Maintenance Instructions

Provides essential safety and procedural instructions for maintenance.

Appendix A RS485-MODBUS Communication Instructions

Appendix B Parameter list

F0 Basic Program Group

Lists parameters for basic program settings like motor control and frequency reference.

F1 Start and Stop Control Group

Details parameters related to inverter start and stop operations.

F2 Motor Parameter Group

Parameters for configuring motor characteristics and auto-tuning.

F3 Motor Vector Control Group

Parameters for advanced vector control modes, speed, and torque.

F4 VF Control Group

Parameters for configuring V/F curves and voltage control.

F5 Digital Input Terminal Group

Configuration settings for digital input terminals and HDI.

F6 Digital Output Terminal Group

Configuration settings for digital and relay output terminals.

F7 Keypad Function Group

Parameters related to keypad operation, lock, and menu modes.

F8 Enhanced Parameter Group

Advanced parameters for jogging, skip frequency, and protection.

F9 Process PID Control Group

Parameters for PID control loop configuration and tuning.

FA Simple PLC and Multi-Preset Speed Control Group

Parameters for simple PLC operation and multi-preset speed settings.

FE Protection and Early Alarm Group

Parameters for various protection and early alarm functions.

Related product manuals