IRIS Touch Quick Installation & Maintenance Guide Version 1.1
Contents
1.
Introduction ................................................................................................
............................
2.
Product Features ................................................................
................................
3.
Package Contents ................................................................
................................
4.
Board Configuration ................................................................
................................
5.
Before You Start ................................................................................................
6.
Installing the IRIS Touch ................................................................
................................
6.1.
Mounting ................................................................
................................
6.2.
Power ................................................................................................
..........................
6.3.
Connections ................................................................
................................
6.4.
GSM SIM card (IRIS Touch 600 & 640) ................................
................................
6.5.
PIN Inputs ................................................................
................................
6.6.
Switch on and test ................................................................
................................
6.7.
GPRS Network Scan (IRIS Touch 600 or 640) ................................
...............................
6.8.
Configuration................................................................
................................
6.9.
Panel configuration ................................................................
................................
6.10.
Testing ................................................................................................
7.
Maintenance ................................................................................................
.........................
7.1.
Confirm current status ................................................................
..............................
7.2.
Communication paths check and communication to ARC
................................
8.
Specifications ................................................................................................
............................
................................
................................
................................
................................
................................
..........................
................................
................................
................................
................................
...............................
................................
................................
.........................
..............................
................................
14
IRIS Touch Quick Installation & Maintenance Guide
Care should be taken when connecting telecommunications equipment to ensure only like interfaces are
connected to avoid safety hazards.
SELV: SELV (Safety Extra-Low
Voltage) is defined as a secondary circuit which is so designed
and protected that under normal and single fault conditions the voltage between any
two accessible parts does not exceed a safe value (42.4V peak or 60V dc maximum)
The interfaces on the IRIS Connect have the following safety classifications:
• Power Interface: SELV for connection to a DC supply
• Inputs: SELV for connection to alarm output pin.
Conformance
European Directives
The IRIS Connect complies with the following European Directives:
• 1999/5/EC (Radio & Telecoms Terminal Equipment Directive)
• 2006/95/EC (Low Voltage Directive)
• 2004/108/EC (Electromagnetic Compatibility Directive)
EN50131, EN50136 (VdS Certified)
The dialler is compliant to the requirements of European Standards:
EN50131-1: 2006 & EN50131-10: 2014
EN50136-1: 2012 & EN50136-2: 2013
Security Grade 4
ATS-SP6 over Ethernet, ATS-SP5 over GPRS, ATS-
DP4 (IRIS Touch 640) / Environmental Class II
EN54-21CPR (VdS Certified)
EN54-21 CPR fire approved
Care should be taken when connecting telecommunications equipment to ensure only like interfaces are
Voltage) is defined as a secondary circuit which is so designed
and protected that under normal and single fault conditions the voltage between any
two accessible parts does not exceed a safe value (42.4V peak or 60V dc maximum)
DP4 (IRIS Touch 640) / Environmental Class II