8. Specifications
Transmission paths 600 620
Ethernet Standard
UTP 10/100 Base T with auto
Rj45 socket for CAT5 cabling
Connection fault detection
Loss of Ethernet synchronisation
GPRS
(3G/4G/CDMA
optional on request)
Standard Quad band GSM
850/900/1800/1900 MHz
Connection SMA socket for GSM
antenna connection
Connection fault detection Loss of registration with
network
IP
TCP ports (outbound) 53165 (Alarms & Polling), 5
1292 (Diagnostic & Reflashing),
Alarm transmission
Interface to monitoring centre IRIS Secure Apps or IRIS Management suite
Serial interface to alarm panel RS485, RS232 (TTL), RS232 x 2
PIN Inputs interface to alarm panel Maximum input voltage range 0V to +24V
Input ‘low’ (alarm) threshold < 1V
Input ‘high’ (restore) threshold > 2V
Internal pull-up impedance 10K to 3.3V supply
Alarm protocols SIA (level 1 to 3)
Contact ID
Fast format (Scancom)
Tamper detection reporting to monitoring centre Serial interface, Pin inputs
Fault reporting to monitoring centre Transmission interface/path fault
Relay outputs
Maximum operating voltage 24V DC
Maximum current rating 100mA DC
Power supply
Supply voltage 9V to 28V DC
Note: For Radio & Telecoms Terminal Equipment Directive
no longer than 3 meters in length
Typical current 97mA @ 12V DC 98mA @ 12V DC
Maximum current 1A @ 12V DC
Recommended external PSU 12V DC 1A 12 Watt
Environmental
Operating temperature range -10°C to 55°C
Operating humidity range 95% max., non-
Weights and dimensions
Physical dimensions 12 cm x 9 cm
PCB weight 60 grams
Fully packaged weight 160 grams
UTP 10/100 Base T with auto
Rj45 socket for CAT5 cabling
Loss of Ethernet synchronisation
Quad band GSM
850/900/1800/1900 MHz
SMA socket for GSM
antenna connection
Loss of registration with
network
1292 (Diagnostic & Reflashing),
10001 (Upload / Download)
Note: For Radio & Telecoms Terminal Equipment Directive
the power cable needs to be
no longer than 3 meters in length
IRIS Touch Quick Installation & Maintenance Guide
1. Introduction
The IRIS Touch offers cost effective Alarm over IP (AoIP) for the
commercial and residential sectors.
All IRIS Touch diallers are certified as suitable for all Grade 4
systems with an Alarm Transmission
System (ATS) configuration up to SP6 for single path, or ATS configuration DP4 for
640 only).
The IRIS Touch
is based on Chiron’s successful IRIS Touch range of AoIP diallers with the same
hardware and software used in all IRIS diallers
; with the same level of security and features provided to
military, governments, banks and commercial industry markets.
The IRIS Touch offers both
polling and alarm via Ethernet or GPRS (3G, 4G and CDMA on
communication paths to the monitoring centre.
This manual describes a quick guide to the installation of products from the IRIS Touch
Engineer manual, including multi-lingual versions, please visit our website at:
http://www.chironsc.com/downloads_security.html
2. Product Features
Features
IRIS Touch
600 620
Ethernet 1
GPRS
Relays 4 4
Inputs (Pins) 6 6
Serial RS485
Serial TTL
RS232 (Basic or Full) 2 x Basic
Text messaging
Multi language menus
VoIP & SIP services
Option available on request 3G / 4G / CDMA
commercial and residential sectors.
systems with an Alarm Transmission
is based on Chiron’s successful IRIS Touch range of AoIP diallers with the same
; with the same level of security and features provided to
polling and alarm via Ethernet or GPRS (3G, 4G and CDMA on
This manual describes a quick guide to the installation of products from the IRIS Touch
. For the full
640