Capacity | 1000 VA |
---|---|
Output Power | 600 W |
Real Power | 600 W |
Input Voltage | 230 V |
Communication Interface | USB, RS-232 |
Operating Temperature | 0-40°C |
Storage Temperature | -15-45°C |
Topology | Line Interactive |
Output Voltage | 230 V |
Frequency Range | 50/60 Hz |
Transfer Time | 4 ms |
Battery Type | Sealed Lead Acid |
Number of Outlets | 4 |
Humidity | 0-95% non-condensing |
Battery Backup Time | 5-15 minutes (depending on load) |
Battery Recharge Time | 4-6 hours to 90% |
Specifies the unit's purpose and provides paramount safety warnings for personnel.
Outlines critical safety warnings, handling, and battery-specific precautions.
Covers environmental considerations, EU declaration, and repacking instructions.
Details hazards associated with batteries, including electrolyte and electrical risks.
Introduces the manual's scope and provides an overview of UPS unit versions.
Explains the meaning of manual symbols and describes the documentation organization.
Guides on receiving, unpacking, and verifying the contents of the UPS package.
Details proper storage conditions, handling procedures, and environmental requirements.
Covers floor/rack loading capacity and ventilation requirements for installation.
Provides instructions for mounting UPS and battery cabinets into rack frames.
Guides on installing UPS and battery cabinets in a floor-standing configuration.
Explains the fundamental operating principles of the UPS in different modes.
Describes UPS operation when connected to AC input power.
Explains UPS operation during mains failure, powered by batteries.
Details the automatic and manual bypass functions of the UPS.
Describes the energy-saving ECO Mode operation.
Explains the function of the UPS as a frequency converter.
Covers additional functionalities like Green Power, Cold Start, and Auto-Restart.
Presents a block diagram illustrating the UPS internal structure and signal flow.
Details the front panel controls and indicators for LED and LCD display units.
Describes the switches, LEDs, operations, and indicator signals for LED-equipped units.
Explains the LCD display, menus, functionalities, and fault indicators for LCD-equipped units.
Illustrates and identifies the connectors on the rear panels of Tower and Rack/Tower units.
Guides through electrical preparations, connections, startup, and shutdown processes.
Details the DB9 (RS232) and USB ports for UPS communication.
Discusses the interface slot for optional communication cards like SNMP or volt-free contacts.
Provides instructions for cleaning the UPS and guidelines for its storage.
Explains battery self-testing procedures and the process for replacing internal batteries.
Covers proper battery disposal and instructions for installing an LCD display front panel.
A comprehensive guide to diagnose and resolve common UPS problems and error indicators.
Lists detailed electrical, mechanical, and environmental specifications for UPS units and battery packs.
Lists electrical, mechanical, and environmental specifications for various UPS models.
Details the specifications for compatible external battery packs.
Provides charts showing estimated backup runtime based on load and external battery configuration.