Digital Power Meter 66203/66204 User’s Manual
5-30
[CONFigure:]CURRent:SHUNt
Type: Channel-Specific or All channels.
Description: This command sets the current shunt of measure.
Setting syntax: CURRent:SHUNt<space><CRD><PMT>
CURRent:SHUNt<space><CRD>,<CRD>,<CRD>,<CRD><PMT>
Setting parameters: <CRD>, HIGH | LOW | AUTO
Query syntax: CURRent:SHUNt?<PMT>
Return parameters: <CRD>, HIGH | LOW | AUTO
Header on: :CURRENT:SHUNT<space><CRD>,<CRD>,<CRD>,<CRD><RMT>
Header off: <CRD>,<CRD>,<CRD>,<CRD><RMT>
Example: none
[CONFigure:]CURRent:INRush:LEVel
Type: All channels.
Description: This command sets the level of trigger of inrush current in Ampere.
Setting syntax: CURRent:INRush:LEVel<space><NR2><PMT>
Setting parameters: <NR2>, 0.1 ~ 10.0
Query syntax: CURRent:INRush:LEVel?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2>, 0.1 ~ 10.0
Header on: :CURRENT:INRUSH:LEVEL<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
[CONFigure:]CURRent:INRush:TIME
Type: All channels.
Description: This command sets the time of measure of inrush current in
Millisecond.
Setting syntax: CURRent:INRush:TIME<space><NR1><PMT>
Setting parameters: <NR1>, 1 ~ 9999
Query syntax: CURRent:INRush:TIME?[<space><MAX | MIN>]<PMT>
Return parameters: <NR1>, 1 ~ 9999
Header on: :CURRENT:INRUSH:TIME<space><NR1><RMT>
Header off: <NR1><RMT>
Example: none
[CONFigure:]CURRent:INRush:DELay
Type: All channels.
Description: This command sets the delay of measure of inrush current in
Millisecond.
Setting syntax: CURRent:INRush:DELay<space><NR1><PMT>
Setting parameters: <NR1>, 0 ~ 9999
Query syntax: CURRent:INRush:DELay?[<space><MAX | MIN>]<PMT>
Return parameters: <NR1>, 0 ~ 9999
Header on: :CURRENT:INRUSH:DELAY<space><NR1><RMT>
Header off: <NR1><RMT>
Example: none
[CONFigure:]MEASure:MODE
Type: All channels.
Description: This command sets the mode of measure.