Digital Power Meter 66203/66204 User’s Manual
5-42
Example: none
[CALCulate:]COMParator:LIMit:CFI
Type: Channel-Specific.
Description: This command sets upper and lower boundaries of current crest
factor in GONG mode.
Setting syntax: COMParator:LIMit:CFI<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99.99, -1 denote don’t care.
Query syntax: COMParator:LIMit:CFI?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99.99
Header on: :COMPARATOR:LIMIT:CFI<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[CALCulate:]COMParator:LIMit:THDI
Type: Channel-Specific.
Description: This command sets upper and lower boundaries of total harmonic
distortion of current in GONG mode.
Setting syntax: COMParator:LIMit:THDI<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99.99, -1 denote don’t care.
Query syntax: COMParator:LIMit:THDI?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99.99
Header on: :COMPARATOR:LIMIT:THDI<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[CALCulate:]COMParator:LIMit:W
Type: Channel-Specific.
Description: This command sets upper and lower boundaries of power in GONG
mode.
Setting syntax: COMParator:LIMit:W<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99999.9999, -1 denote don’t care.
Query syntax: COMParator:LIMit:W?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99999.9999
Header on: :COMPARATOR:LIMIT:W<space><NR2>,<NR2><RMT>
Header off: <NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example: none
[CALCulate:]COMParator:LIMit:PF
Type: Channel-Specific.
Description: This command sets upper and lower boundaries of power factor in
GONG mode.
Setting syntax: COMParator:LIMit:PF<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 9.999, -1 denote don’t care.