Page | 73
By default, the Ring Buffer is enabled. In this mode, the earliest segment will be overwritten with a new
one as soon as the record buffer is full. New segments will be created until the recording is stopped via
the red shutter button on the top or the camera, or the stop button on the Main screen. This behavior can
be changed by checking the Disable Ring Buffer option. When the Ring Buffer is disabled, the camera will
stop recording when the buffer is full, and segments will not be overwritten.
Control
Function
Record Length
(Seconds)
Set the duration of the recorded segment, in seconds. The timing of this
recording can be changed in the Trigger Delay window.
Record Length
(frames)
Set the duration of the recorded segment, in frames. The timing of this recording
can be changed in the Trigger Delay window.
Max Button
Sets record length to the maximum available for your camera model and the
selected number of segments.
Number of
Segments
The maximum number of full-size segments that can be held in memory is
65,536.
Each time a recording is triggered, it is saved into a subsequent region of
memory. If a recording is stopped early, the unused recording time is returned
for future segments to use. For example, two 0.5-second segments can be
recorded instead of one 1-second segment.
Disable Ring
Buffer
When the buffer is full of segments, stop recording instead of overwriting the
oldest segment with new frames.
OK Button
Applies changes and closes window. OK must also be selected in the Record
Settings window after the Record Mode window has closed, otherwise the
changes will be discarded.
Cancel Button
Discards changes to the Record Mode.
NOTE: In Segmented Mode, new recordings can only be started using either the shutter button
on top of the camera, or the Record button on the main screen. New segments are only started
when a trigger signal configured as a Record End Trigger is active.